Standard Proximity Sensor E2E CSM_E2E_DS_E_11_4 Your Search for Proximity Sensors Starts with the World-leading Performance and Quality of the E2E (Standards do not apply to all models.) • Standard Sensors for detecting ferrous metals. • Wide array of variations. Ideal for a variety of applications. • Models with different frequencies are also available to prevent mutual interference.
E2E Lineup includes models with self-diagnostic output to provide notification of failures and unstable detection conditions, such as coil burnout. • Contributes to preventive maintenance to keep the line from stopping. Reduced wiring, fewer resources, and low power consumption contribute to environmentalism. • Wiring work and amount of copper wire used reduced to two thirds of that required for 3-wire models.
E2E E2E Guide to Selection by Purpose Environment −40 to 85°C AC 2-wire: M12 to M30, DC 3-wire: M8 to M30 Wide operating temperature range −25 to 70°C Models not listed above.
E2E E2E Model Number Legend E2E- A B C D E F G - H I - J - K - L No.
E2E Ordering Information 2-Wire Models Shielded DC 2-wire Models with No Self-diagnostic Output [Refer to Dimensions on page 27.] Appearance Sensing distance Connection method Cable specifications Polarity M12 Pre-wired Smart- PUR (increased click Connector Mod- oil-resistant) els (0.
E2E 2-Wire Models Shielded DC 2-Wire UL-recognized Models with No Self-diagnostic Output [Refer to Dimensions on page 27.] Appearance M8 Sensing distance 2 mm Connection method Cable specifications Polarity M12 Pre-wired Smartclick Connector Models (0.3 m) 3 mm M18 7 mm Pre-wired Models (2 m) M30 10 mm M12 Pre-wired Smartclick Connector Models (0.
E2E 2-Wire Models Unshielded DC 2-Wire Models with No Self-diagnosis Output [Refer to Dimensions on page 27.] Appearance Sensing distance Connection method Cable specifications Polar- Operation ity mode NO Pre-wired Models (2 m) PVC (oil-resistant) M8 M12 Connector Models 4 mm NC --- M8 Connector Models --- M12 Pre-wired Smartclick Connector Models (0.3m) PVC (oil-resistant) M12 M12 Connector Models --- M12 Standard Prewired Connector Models (0.
E2E 2-Wire Models Unshielded DC 2-Wire UL-recognized Models with No Self-diagnostic Output [Refer to Dimensions on page 27.] Appearance M8 Sensing distance Connection method Cable specifications Polarity Operation mode M12 Pre-wired Smartclick Connector Models (0.
E2E 2-Wire Models Unshielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 27.
E2E 2-Wire Models AC 2-Wire Models Shielded Models [Refer to Dimensions on page 27.] Appearance M8 Sensing distance Connection method Pre-wired Models (2 m) 1.
E2E 3-Wire Models Shielded DC 3-Wire Models [Refer to Dimensions on page 27.] Appearance Sensing distance Connection method Pre-wired Models (2 m) M8 1.
E2E 3-Wire Models Unshielded DC 3-Wire Models [Refer to Dimensions on page 27.
E2E Ratings and Specifications E2E-X@D@ DC 2-Wire Models Size Shielded Item M8 Shielded M12 Unshielded Model E2E-X2D@ Shielded M18 Unshielded Shielded M30 Unshielded Shielded Unshielded E2E-X4MD@ E2E-X3D@ E2E-X8MD@ E2E-X7D@ E2E-X14MD@ E2E-X10D@ E2E-X20MD@ Sensing distance 2 mm ±10% 4 mm ±10% 3 mm ±10% 8 mm ±10% 7 mm ±10% 14 mm ±10% 10 mm ±10% 20 mm ±10% Set distance *1 0 to 1.6 mm 0 to 3.2 mm 0 to 2.4 mm 0 to 6.4 mm 0 to 5.6 mm 0 to 11.
E2E E2E-X@Y@ AC 2-Wire Models Size Shielded Item M8 Shielded Model E2E-X1R5Y@ M12 Unshielded E2E-X2MY@ Shielded E2E-X2Y@ M18 Unshielded E2E-X5MY@ Shielded E2E-X5Y@ M30 Unshielded Shielded Unshielded E2E-X10MY@ E2E-X10Y@ E2E-X18MY@ Sensing distance 1.5 mm ±10% 2 mm ±10% 5 mm ±10% 10 mm ±10% 18 mm ±10% Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm 0 to 14 mm Differential travel 10% max.
E2E E2E-X@T1 AC/DC 2-Wire Models Size M12 M18 E2E-X3T1 E2E-X7T1 Shielded Item M30 Shielded Model E2E-X10T1 Sensing distance 3 mm ±10% 7 mm ±10% 10 mm ±10% Set distance 0 to 2.4 mm 0 to 5.6 mm 0 to 8 mm Differential travel 10% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 17.) Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm Iron, 30 × 30 × 1 mm DC 1 kHz 0.5 kHz 0.
E2E E2E-X@E@/F@ DC 3-Wire Models Size Shielded M8 Shielded M12 Unshielded Shielded Shielded Unshielded E2E -X10ME@/F@ E2E-X10E@/ F@ E2E -X18ME@/F@ Sensing distance 1.5 mm ±10% 2 mm ±10% 5 mm ±10% 10 mm ±10% 18 mm ±10% Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm 0 to 14 mm Differential travel 10% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 18.
E2E Engineering Data (Reference Value) Sensing Area Shielded Models E2E-X@E@/-X@Y@/-X@F@ 12 Distance X (mm) Distance X (mm) E2E-X@D@/-X@T1 E2E-X10 10 8 E2E-X7 6 E2E-X10 10 Y 8 X 6 E2E-X3 E2E-X5 E2E-X2 Y 4 12 E2E-X2 4 X 2 0 −20 E2E -X1R5 2 −15 −10 −5 0 5 0 −15 10 15 Distance Y (mm) −10 −5 0 5 10 Distance Y (mm) Unshielded Models E2E-X@ME@/-X@MY@/-X@MF@ Distance X (mm) Distance X (mm) E2E-X@MD@ 30 25 20 30 Y X 25 20 E2E-X18M E2E -X20M 15 E2E-X10M Y 10 10 X E2E
25 d× d t = 1 mm X 20 15 E2E-X1R5E@/-X1R5Y@/-X1R5F@ 10 20 30 40 d× d X Iron 20 50 70 X t = 1 mm Iron 2.0 Stainless steel (SUS304) 1.5 t = 1 mm Stainless steel (SUS304) 1.0 Brass Aluminum Copper Brass 0 Aluminum 0.
E2E Leakage Current 0.8 E2E-X10D1-N 0.6 E2E-X3D1-N E2E-X@T1 Leakage current (mA) E2E-X@Y@ 1.0 Leakage current (mA) Leakage current (mA) E2E-X@D@ 1.4 1.2 1.0 0.8 1.4 1.2 AC power 1.0 0.8 DC power 0.6 0.4 E2E-X2D1-N 0.6 Protective resistance 0.4 mA 0.4 ~ E2E-X7D1-N 0.2 V ~ 0.2 AC power Proximity Sensor (OFF) 0 5 10 15 20 25 30 0 50 100 150 Power supply voltage (V) 200 0.
E2E I/O Circuit Diagrams E2E-X@D@ DC 2-Wire Models Operation mode Model Timing Chart Output circuit Polarity: Yes 1 E2E-X@D1-N E2E-X@D1-M1G(J) E2E-X@D1(-M1TGJ)-U E2E-X@D1-M3G E2E-X@D1(-M1TGJ)-US Set position Unstable Non-sensing sensing area area Stable sensing area Proximity Sensor Sensing object Without selfdiagnostic output: NO Proximity Sensor main circuit Load Brown +V 4 0V Blue Note: The load can be connected to either the +V or 0 V side.
E2E DC 3-Wire Models Operation mode Output specifications Model Timing Chart Sensing object Present Not present Operation indicator (red) NO 1 +V ON 100 Ω OFF Control output (between brown and black leads) Output voltage (between black and blue leads) E2E-X@E@ NPN output E2E-X@E@-M1 E2E-X@E@-M3 Output circuit Brown Load ON Proximity Sensor main circuit OFF High Low Constant current* 4 2 Black Tr 3 0V Present Sensing object Blue Not present Operation indicator (red) *Constant curre
E2E Sensor I/O Connectors (Sockets on One Cable End) Model for Connectors and Pre-wired Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately. [Refer to Dimensions for the XS2, XS3, and XS5.
E2E Connections for Sensor I/O Connectors Type Operation mode Model Sensor I/O Connector model number 1: Straight 2: L-shape 1 DC 2-wire (IEC pin wiring) E2E-X@D1-M1G/M1GJ XS2F-D42@-@A0-F D: 2-m cable G: 5-m cable 1: Straight 2: L-shape 2 DC 2-wire (previous pin wiring) E2E-X@D1-M1 XS2F-D42@-@D0 Connections E2E Main circuit Proximity Sensor D: 2-m cable G: 5-m cable 3 DC 2-wire (no polarity) NO E2E-X@D1-M1J-T XS2F-D42@-@D0 D: 2-m cable G: 5-m cable 4 DC 2-wire (M8 connector) E2E-X@D1-
E2E Operation mode Model Sensor I/O Connector model number 1: Straight 2: L-shape 10 NO E2E-X@E/F1-M1 XS2F-D42@-@C0-F Connections E2E Main circuit Proximity Sensor Type D: 2-m cable G: 5-m cable DC 3-wire 1: Straight 2: L-shape 11 NC E2E-X@E2/F2-M1 XS2F-D42@-@80-F D: 2-m cable G: 5-m cable NO E2E-X@E1/F1-M3 2: 2-m cable 5: 5-m cable DC 3-wire (M8 connector) 1: Straight 2: L-shape NC 13 XS3F-M42@-40@-A E2E-X@E2/F2-M3 XS3F-M42@-40@-A 2: 2-m cable 5: 5-m cable 14 NO E2E-X@Y1-M1 X
E2E Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. CAUTION • Do not short the load. Explosion or burning may result. • Do not supply power to the Sensor with no load, otherwise Sensor may be damaged. Precautions for Correct Use Relationship between Sizes and Models Do not use this product under ambient conditions that exceed the ratings.
E2E Mutual Interference Mutual Interference When installing Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained.
E2E (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
E2E Pre-wired Models (Shielded) Pre-wired Models (Unshielded) Diagram 1 Diagram 2 E2E-X2D@ E2E-X1R5E@/F@ 30 7 30 15 dia. 15 dia. 26 13 3 8 E2E-X2MY@ 40 13 8 7 36 15 dia. 3 *1 *1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m Robotics Cable Models: 4-dia.
E2E Pre-wired Models (Shielded) Diagram 9 Pre-wired Models (Unshielded) E2E-X3T1 60 21 dia. 9 55 17 4 10 --- *1 M12 × 1 Indicators *2 Two clamping nuts *1 4-dia. vinyl-insulated round cable with 2 Toothed conductors (Conductor cross section: 0.3 mm2, washer Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). *2 Operation indicator (red), Setting indicator (green) Diagram 10 E2E-X7D@/E2E-X5E@/F@ E2E-X5Y@/E2E-X7T1 43 29 dia.
E2E M8 Connector Models (Shielded) M8 Connector Models (Unshielded) Diagram 24 E2E-X2D@-M3G/E2E-X1R5E@-M3/X1RF@-M3 Diagram 25 E2E-X4MD@-M3G/E2E-X2ME@-M3/X2MF@-M3 39 39 31 15 dia. 26 8 3 13 31 15 dia. M8 × 1 26 6 13 Operation indicator (red), Setting indicator (green) D2/E/F Models: Operation indicator (red) M8 × 1 8 3 * D Models: M8 × 1 * D Models: Operation indicator (red), Setting indicator (green) D2/E/F Models: Operation indicator (red) 6.1 dia.
E2E Diagram 20 E2E-X7D@-M1(G)/E2E-X5E@-M1/X5F@-M1 E2E-X5Y@-M1 53 29 dia. Diagram 21 E2E-X14MD@-M1(G)/E2E-X10ME@-M1 X10MF@-M1 E2E-X10MY@-M1 53 38 4 24 38 29 dia. 10 M12 × 1 10 24 10 4 M12 × 1 14.8 dia. Indicators* M18 × 1 * D1 Models: Two clamping nuts Toothed washer Operation indicator (red), Setting indicator (green) D2/E/Y Models: Operation indicator (red) Diagram 22 E2E-X10D@-M1(G)/E2E-X10E@-M1/X10F@-M1 E2E-X10Y@-M1 58 42 dia.
E2E Pre-wired Connector Models (Shielded) Diagram 26 E2E-X2D@-M1TGJ-U *3 E2E-X2D1-M1TGJ E2E-X2D@-M1TGJ-US 30 15 dia. 7 26 8 13 3 *1 Indicators *2 M12 × 1 Two clamping nuts *1. No U suffix: 4-dia. Vinyl-insulated round cable Toothed washer M8 × 1 U suffix: 4-dia. Polyurethane insulated round cable, Standard length: 300 mm *2. D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) *3. The connectors for M1TGJ models are XS5 Smartclick connectors.
E2E Pre-wired Connector Models (Unshielded) Diagram 30 E2E-X4MD@-M1TGJ-US 30 15 dia. 7 26 13 6 8 3 6.1 dia. *1 Indicators *2 Two clamping nuts Toothed washer M8 × 1 Diagram 31 E2E-X8MD1-M1GJ E2E-X8MD1-M1TGJ E2E-X8MD@-M1TGJ-US 38 21 dia. M12×1 *1. 4-dia. vinyl-insulated round cable Standard length: 300 mm *2. D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) 9 33 10 4 7 17 9 dia.
E2E Dimensions for Proximity Sensors with Sensor I/O Connectors Shielded Models Straight Connectors Unshielded Models Straight Connectors L1 L-shape Connectors L1 L-shape Connectors Dimensions with the XS2F/XS5F Connected Dimension Sensor diameter M8 DC M12* AC M18 M30 (Unit: mm) L1 L2 Approx. 75 Approx. 80 Approx. 85 Approx. 85 Approx. 90 Approx. 62 Approx. 67 Approx. 72 Approx. 72 Approx.
Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron).