Datasheet
21E2E
Mutual Interference
When installing two or more Sensors face to face or side by side, ensure that the minimum distances given in the following table are maintained.
Precautions for Safe Use
The colors in parentheses are previous wire colors.
Model Item M8 M12 M18 M30
E2E-X@D@
DC 2-wire
E2E-X@T1
AC/DC 2-wire
Shielded A 20 mm 30 (20) mm 50 (30) mm 100 (50) mm
B 15 mm 20 (12) mm 35 (18) mm 70 (35) mm
Unshielded A 80 mm 120 (60) mm 200 (100) mm 300 (100) mm
B 60 mm 100 (50) mm 110 (60) mm 200 (100) mm
E2E-X@E@
E2E-X@F@
DC 3-wire
E2E-X@Y@
AC 2-wire
Shielded A 20 mm 30 (20) mm 50 (30) mm 100 (50) mm
B 15 mm 20 (12) mm 35 (18) mm 70 (35) mm
Unshielded A 80 mm 120 (60) mm 200 (100) mm 300 (100) mm
B 60 mm 100 (50) mm 110 (60) mm 200 (100) mm
A
B
  WARNING
This product is not designed or rated for ensuring safety 
of persons. 
Do not use it for such purposes.
Item Examples
Power supply
Do not impose an excessive voltage on the 
E2E, otherwise it may explode or burn. Do 
not impose 100 VAC on any E2E DC Model, 
otherwise it may explode or burn.
Load short-circuit
Do not short-circuit the load, or the E2E may 
explode or burn.
The E2E short-circuit protection function is 
valid if the polarity of the supply voltage im-
posed is correct and within the rated voltage 
range.
Wiring
Be sure to wire the E2E and load correctly, 
otherwise it may explode or burn.
Connection with no load
Make sure to connect a proper load to the 
E2E in operation, otherwise it may explode or 
burn.
DC 3-wire Models
Sensor
Brown 
Black
Blue 
Load
Incorrec
t
DC 2-wire Models
Sensor
Brown 
Blue 
Load
Incorrect
DC 3-wire Models (NPN output)
Sensor
Brown 
Black
Blue 
Load
Incorrect
(Load 
short- 
circuit)
DC 2-wire Models
Sensor
Brown 
Blue 
Load
Incorrect
(Load short-circuit)
The following diagram shows that the load is 
short-circuited while the polarity of the supply 
voltage imposed on the E2E/E2E2 is wrong, 
in which case the E2E/E2E2 may explode or 
burn.
DC 3-wire Models (NPN output)
Sensor
Brown 
Blue 
Load
Black
Sensor
Brown 
Black 
Load
Blue
Incorrect Incorrect
DC 3-wire Models
Sensor
Brown 
Blue 
Load
Incorrect
AC 2-wire Models
Sensor
Brown 
Blue 
Load
Incorrec
t