Datasheet
27E2E
Pre-wired Models
(Shielded)
Pre-wired Models
(Unshielded)
Fig. 10 : E2E-X2Y@ Fig. 11 : E2E-X5MY@
Fig. 12 : E2E-X3T1
Fig. 13 : E2E-X7D@-N/
E2E-X5E@/F@
E2E-X5Y@/E2E-X7T1
Fig. 14 : E2E-X14MD@/
E2E-X10ME@/F@
E2E-X10MY@
Fig. 15 : E2E-X10D@-N/
E2E-X10E@/F@
E2E-X10Y@/
E2E-X10T1
Fig. 16 : E2E-X20MD@/
E2E-X18ME@/F@
E2E-X18MY@
4-dia. round cable with 2 conductors
(Conductors cross section:
0.3 mm
2
, Insulator diameter: 1.3 mm),
Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
4-dia. cable with 2 conductors
(Conductors cross section: 0.3 mm
2
, Insulator diameter: 1.3 mm),
Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
Note: Operation indicator (red), setting indicator
(green)
4-dia. round cable with
2 conductors (Conductors cross
section: 0.3 mm
2
,
Insulator diameter: 1.3 mm),
Standard length: 2 m
The cable can be extended up to
200 m (separate metal conduit).
6-dia. round cable with 2 conductors
(D, Y, T Models)/3 conductors
(D@S, E, F Models)
(Conductor cross section: 0.5 mm
2
,
Insulator diameter: 1.9 mm)
Standard length: 2 m
Robotics cable Models: 6-dia. vinyl-
insulated round cable with 2 conductors
(D Models)/3 conductors (E Models)
(Conductor cross section: 0.5 mm
2
,
Insulator diameter: 1.74 mm)
Standard length: 2 m
The cable can be extended (separate
metal conduit) up to 200 m (control
output) or up to 100 m (diagnostic
output).
Note: D, T Models: Operation indicator (red),
setting indicator (green);
E, F, Y Models: Operation indicator (red)
Note: D, T Models: Operation indicator (red),
setting indicator (green);
E,F,Y Models: Operation indicator (red)
6-dia. round cable with 2 conductors
(D, Y, T Models)/3 conductors (D@S, E, F
Models)
(Conductor cross section: 0.5 mm
2
, Insulator
diameter: 1.9 mm)
Standard length: 2 m
Robotics cable models: 6-dia. vinyl-insulated
round cable with 2 conductors (D Models)/
3 conductors (E Models) (Conductor cross
section: 0.5 mm
2
, Insulator diameter: 1.74 mm)
Standard length: 2 m
The cable can be extended (separate metal
conduit) up to 200 m (control output) or up to
100 m (diagnostic output).
Note: D Models: Operation indicator (red),
setting indicator (green);
E, F, Y Models:
Operation indicator (red)
6-dia. round cable with 2 conductors
(D, Y, T Models)/3 conductors
(D@S, E, F Models)
(Conductor cross section:
0.5 mm
2
, Insulator diameter: 1.9 mm),
Standard length: 2 m
Robotics cable Models: 6-dia. vinyl-
insulated round cable with
2 conductors (D Models)/3
conductors (E Models)
(Conductor cross section: 0.5 mm
2
,
Insulator diameter: 1.74 mm),
Standard length: 2 m
The cable can be extended
(separate metal conduit) up to 200 m
(control output) or up to 100 m
(diagnostic output).
Note: D Models:
Operation indicator (red),
setting indicator (green);
E, F, Y Models: Operation indicator (red)
6-dia. round cable with 2 conductors
(D, Y, T Models)/3 conductors
(D@S, E, F Models)
(Conductor cross section: 0.5 mm
2
,
Insulator diameter: 1.9 mm),
Standard length: 2 m
Robotics cable Models: 6-dia. vinyl-
insulated round cable with
2 conductors (D Models)/
3 conductors (E Models) (Conductor
cross section: 0.5 mm
2
,
Insulator diameter: 1.74 mm),
Standard length: 2 m
The cable can be extended
(separate metal conduit) up to 200 m
(control output) or up to 100 m
(diagnostic output).
Pre-wired e-CON connector Model
1
15
2
3
4
5.9
15.6
Connector:
Product code 37104-2206-000FL
(Sumitomo 3M)
Pre-wired e-CON connector Model
1
15
2
3
4
5.9
15.6
Connector:
Product code 37104-2206-000FL
(Sumitomo 3M)
Pre-wired e-CON connector Model
1
15
2
3
4
5.9
15.6
Connector:
Product code
37104-2206-000FL
(Sumitomo 3M)
Pre-wired e-CON connector Model
1
15
2
3
4
5.9
15.6
Connector:
Product code
37104-2206-000FL
(Sumitomo 3M)
21 dia.
4
17
38
10
9
43
M12 × 1
Operation indicator (red)
Two clamping nuts
Toothed washer
21 dia.
9 dia.
47
17
38
10
9
43
M12 × 1
Operation indicator (red)
Two
clamping nuts
Toothed washer
M12 × 1
Indicator (See note.)
Two
clamping nuts
Toothed washer
4
21 dia.
17
55
10
9
60
M18 × 1
Indicator
(See note.)
Two
clamping nuts
Toothed washer
29 dia.
24
4
38
10
12
43
14.8 dia.
Indicator
(See note.)
M18 × 1
Two
clamping nuts
Toothed washer
29 dia.
24
4
38
10
12
43
10
M30 × 1.5
Indicator (See note.)
Two clamping nuts
Toothed washer
42 dia.
36
5
43
10
12
48
26.8 dia.
M30 × 1.5
Indicator
(See note.)
Two
clamping nuts
Toothed washer
42 dia.
36
5
43
13
10
12
48