Datasheet

20 Inductive Sensors
Precautions
Mounting
Do not tighten the nut with excessive force. A washer must be used
with the nut.
Note: The table below shows the tightening torques for part A and part B nuts.
In the previous examples, the nut is on the sensor head side (part B) and
hence the tightening torque for part B applies. If this nut is in part A, the
tightening torque for part A applies instead.
Influence of Surrounding Metal
When mounting the E2E within a metal panel, ensure that the clea-
rances given in the following table are maintained. Failure to main-
tain these distances may cause deterioration in the performance of
the sensor.
Relationship between Sizes and Models
E2E
Shielded Model Unshielded Model
Part B Part A
Part B Part A
Model Part A Part B
Length Torque Torque
M8 Shielded 9 mm 9 N·m 12 N·m
Unshielded 3 mm
M12 30 N·m
M18 70 N·m
M30 180 N·m
d dia.
Model Item M8 M12 M18 M30
E2E-X@D@
DC 2-wire
E2E-X@T1
AC/DC 2-wire
Shielded l 0 mm 0 mm 0 mm 0 mm
d 8 mm 12 mm 18 mm 30 mm
D 0 mm 0 mm 0 mm 0 mm
m 4.5 mm 8 mm 20 mm 40 mm
n 12 mm 18 mm 27 mm 45 mm
Unshielded l 12 mm 15 mm 22 mm 30 mm
d 24 mm 40 mm 70 mm 90 mm
D 12 mm 15 mm 22 mm 30 mm
m 8 mm 20 mm 40 mm 70 mm
n 24 mm 40 mm 70 mm 90 mm
E2E-X@E@
E2E-X@F@
DC 3-wire
E2E-X@Y@
AC 2-wire
DC 3-wire
E2E2-X@Y@
AC 2-wire
Shielded l 0 mm 0 mm 0 mm 0 mm
d 8 mm 12 mm 18 mm 30 mm
D 0 mm 0 mm 0 mm 0 mm
m 4.5 mm 8 mm 20 mm 40 mm
n 12 mm 18 mm 27 mm 45 mm
Unshielded l 6 mm 15 mm 22 mm 30 mm
d 24 mm 40 mm 55 mm 90 mm
D 6 mm 15 mm 22 mm 30 mm
m 8 mm 20 mm 40 mm 70 mm
n 24 mm 36 mm 54 mm 90 mm
Model Model No.
M8 Shielded E2E-X2D@
E2E-X1R5E@/F@
E2E-X1R5Y@
Unshielded E2E-X4MD@
E2E-X2ME@/F@
E2E-X2MY@
M12 Shielded E2E-X3D@
E2E-X2E@/F@
E2E-X2Y@
E2E-X3T1
Unshielded E2E-X8MD@
E2E-X5ME@/F@
E2E-X5MY@
M18 Shielded E2E-X7D@
E2E-X5E@/F@
E2E-X5Y@
E2E-X7T1
Unshielded E2E-X14MD@
E2E-X10ME@/F@
E2E-X10MY@
M30 Shielded E2E-X10D@
E2E-X10E@/F@
E2E-X10Y@
E2E-X10T1
Unshielded E2E-X20MD@
E2E-X18ME@/F@
E2E-X18MY@
Model Model No.