Datasheet
16 Inductive Sensors
Installation
Connection
E2E
E2E-X@D@
DC 2-wire Models
(Without Diagnostic Output)
E2E-X@Y@
AC 2-wire Models
E2E-X@T1
AC/DC 2-wire Models
E2E-X@D1S
DC 3-wire Models
(With Diagnostic Output)
E2E-X@D1-M1J-T
DC 2-wire Models
(No Polarity)
E2E-X@Y@
AC 2-wire Models
E2E-X@T1
AC/DC 2-wire Models
Blue
Load
Load
Brown
Brown
Blue
Power
supply
Power
supply
Orange
Blue
Brown
Load
Load
Load
Blue
Brown
Power
supply
Note: The load can be connected
as shown above.
Note: The control output and
diagnostic output share the
negative common terminal.
Therefore, the loads must be
connected to the positive
sides of the control output
and diagnostic output.
Note: There is no need to be
concerned about the polarity
(Brown/Blue) of the
Proximity Sensor.
Connected to PC
E2E-X@D@
DC 2-wire Models
E2E-X@E@
DC 3-wire Models
Connected to Relay Load
E2E-X@D@
DC 2-wire Models
E2E-X@E@
DC 3-wire Models
E2E-X@F@
DC 3-wire Models
24 VDC
Blue
Brown
24 VDC
Brown
Blue
24 VDC
Blue
Brown
Black
Blue
Brown
Black
Brown
Blue
Black