Datasheet

XS5 NEXT Series
93
XS5 NEXT Series XS3XS5E2E/E2EQ NEXT Series DC 2-wire E2E/E2EQ NEXT Series DC 3-wire
Setup
Do not install the Connectors with a load placed directly on the joint
or at the point where the wires connect to the Connector.
The Connector may be damaged or the wires in the cable may be
disconnected.
If bending cables, ensure that these use a minimum bend radius of
40 mm.
Connecting
1. Connecting the XS5 Plug and Socket
Align the projection on the plug cover with the polarity key on the
socket, then insert the plug all the way in.
Hold the knurled socket grip, then insert the projection on the plug
into the groove of the socket.
Turn the knurled grips of the socket clockwise approximately 1/8
turn in respect to the plug. A click will indicate that the Connectors
are locked. The locking condition can also be confirmed by the
alignment marks on the plug and socket.
2. Connecting the XS5 and XS2
Align the projection on the plug cover with the polarity key on the
socket, then insert the plug all the way in.
In the same way as when connecting two XS2 Connectors, screw
the knurled grip in the clockwise direction.
When mating the products to XS2 or other M12 Connectors,
tighten the lock to a torque of 0.39 to 0.49 N
-
m.
Please do not bend
from the root portion on the cable
Providing a straight section
from the root portion on the cable
The radius of
40 mm or more
Protrusion on
cover aligns with
polarity key.
Polarity key
Fixtures (grip)
Socket
Plug