Datasheet
E2E/E2EQ NEXT Series
78
PNP output
Please contact your OMRON sales representative regarding assignment of data.
*1. For models with IO-Link, the operation mode can be changed by the IO-Link communications.
*2. If using a model with IO-Link as a general sensor or using a model without IO-Link, it operates in the standard I/O mode (SIO mode).
*
5
*
5
*
4
*
4
*
5
*
4
Sensing
object
(%)
100 080 20
Nonsensing
area
Unstable
Sensing
area
Rated Sensing distance
Stable
Sensing area
Set position
ProximitySensor
Excessive proximity judgment distance
*7
Flashing
(1sec cycle)
Flashing
(1sec cycle)
Flashing
(1sec cycle)
Output mode
Standard
I/O mode
(SIO mode)
*2
NO+NC
NO
NC
NO
Operation
mode
*1
Comunication indicator (green) : Always OFF
Operation indicator (orange)
ON
ON
OFF
ON
OFF
OFF
Control output
*3
Comunication indicator (green) : Always OFF
Operation indicator (orange)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Control output
*3
Comunication indicator (green) : Always OFF
Operation indicator (orange)
Comunication indicator (green)
Operation indicator (orange)
Comunication indicator (green)
Operation indicator (orange)
Comunication indicator (green)
Operation indicator (orange)
Control output 1
*3
Control output 2
*3
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Control output1 (PD1_bit0)
*3
1
0
1
0
Excessive proximity detection (PD1_bit5)
Control output (PD1_bit0)
*3
Instability detection
*6 (PD1_bit4)
Excessive proximity detection (PD1_bit5)
Control output (PD1_bit0) *3
Instability detection *6 (PD1_bit4)
Excessive proximity detection (PD1_bit5)
Instability detection
*6 (PD1_bit4)
1
0
NC
NO+NC
ON
OFF
IO-Link
Communication
mode
(COM mode)
Control output2 (PD1_bit1)
*3
*3. The timer function of the control
output can be set up by the IO-Link
communications. (It is able to select
ON delay, OFF delay, or one-shot
function and select a timer time of 1
to 16,383ms (T).)
*4. The excessive proximity diagnosis
function can be selected by the IO-
Link communications.
*5. The instability detection diagnosis
can be selected by the IO-Link
communications.
*6. The judgment time for the instability
detection diagnosis can be selected
by the IO-Link communications.
(For the ON delay timer function, the
setting can be selected from 0
(invalid), 10, 50, 100, 300, 500, or
1000 ms.)
*7. The judgment distance of the
excessive proximity diagnosis
function can be selected by the IO-
Link communications.
(The distance can be selected as a
combination of the material of the
object detected, such as iron,
aluminum, or SUS and the judgment
distance of approximately 10, 20, or
30%. However, it is not allowed to
select a combination of aluminum
and 30%.)
Please contact your OMRON sales
representative regarding the IO-Link
setup file (IODD file).
ON delay OFF delay
1
0
1
0
NO
NC
ON
OFF
ON
OFF
T
T
Present
Not
present
Sensing
object
NO
NC
ON
OFF
ON
OFF
1
0
1
0
T
T
Present
Not
present
Sensing
object
One shot
1
0
1
0
T
T
NO
NC
ON
OFF
ON
OFF
Present
Not
present
Sensing
object