Datasheet

E2E/E2EQ NEXT Series
64
E2E NEXT Series (Double/Single distance model)
DC 3-wire
Unshielded
Types Double distance model Single distance model
Size M8 M12 M18 M30 M8 M12 M18 M30
Item Model E2E-X4M@8 E2E-X8M@12
E2E-X16M
@
18 E2E-X30M
@
30
E2E-X2M@8 E2E-X5M@12
E2E-X10M
@
18 E2E-X18M
@
30
Sensing distance 4 mm±10% 8 mm±10% 16 mm±10% 30 mm±10% 2 mm±10% 5 mm±10% 10 mm±10% 18 mm±10%
Setting distance 0 to 3.2 mm 0 to 6.4 mm 0 to 12.8 mm 0 to 24 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm 0 to 14.4 mm
Differential travel 15% max. of sensing distance 10% max. of sensing distance
Detectable object Ferrous metals (For non-ferrous metals, refer to the Engineering Data on page 68.)
Standard sensing
object
Iron,
12 × 12 × 1 mm
Iron,
24 × 24 × 1 mm
Iron,
48 × 48 × 1 mm
Iron,
90 × 90 × 1 mm
Iron,
8 × 8 × 1 mm
Iron,
15 × 15 × 1 mm
Iron,
30 × 30 × 1 mm
Iron,
54 × 54 × 1 mm
Response frequency
*1
1,000 Hz 800 Hz 400 Hz 100 Hz 1,000 Hz 800 Hz 400 Hz 100 Hz
Power supply voltage 10 to 30 VDC (including 10% ripple (p-p)), Class 2
Current consumption
1-output models: 16 mA max.
2-output models: 20 mA max.
Output configuration
B@ Models: PNP open collector
C@ Models: NPN open collector
Operation mode
(with sensing object
approaching)
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C3): NC (Normally closed)
2-output models (B3, C3): NO+NC (Normally open, Normally closed)
*3
Control
output
Load
current
1-output models:
10 to 30 VDC,
Class 2, 200 mA
max., (-40 to
70°C), 100 mA
max., (70 to 85°C)
2-output models:
10 to 30 VDC,
Class 2, 50 mA
max.
1-output models:
10 to 30 VDC, Class 2, 200 mA max.,
2-output models:
10 to 30 VDC, Class 2, 100 mA max.
1-output models:
10 to 30 VDC,
Class 2, 200 mA
max., (-40 to
70°C), 100 mA
max., (70 to 85°C)
2-output models:
10 to 30 VDC,
Class 2, 50 mA
max.
1-output models:
10 to 30 VDC, Class 2, 200 mA max.,
2-output models:
10 to 30 VDC, Class 2, 100 mA max.
Residual
voltage
1-output models:
2 V max. (Load
current: 200 mA,
Cable length: 2 m),
2-output models:
2 V max. (Load
current: 50 mA,
Cable length: 2 m)
1-output models:
2 V max. (Load current: 200 mA, Cable length: 2
m),
2-output models:
2 V max. (Load current: 100 mA, Cable length: 2
m)
1-output models:
2 V max. (Load
current: 200 mA,
Cable length: 2 m),
2-output models:
2 V max. (Load
current: 50 mA,
Cable length: 2 m)
1-output models:
2 V max. (under load current of 200 mA with
cable length of 2 m),
2-output models:
2 V max. (under load current of 100 mA with
cable length of 2 m)
Indicator *2
In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit)
In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals)
Protection circuits Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection
Ambient temperature
range
Operating/Storage: -40 to 85°C (with no icing or condensation)
Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C.
Ambient humidity
range
Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance
(destruction)
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
(destruction)
500 m/s
2
10 times
each in X, Y, and
Z directions
1,000 m/s
2
10 times each in X, Y, and Z
directions
500 m/s
2
10 times
each in X, Y, and
Z directions
1,000 m/s
2
10 times each in X, Y, and Z
directions
Degree of protection
Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex
1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards
*4 (Cutting oil type: specified in JIS K 2241:2000; Temperature:
35°C max.)
Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K
Connection method
Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Models (M12 Connector,
M8 (4-pin) Connector and M8 (3-pin) Connector)
Weight *5
(packed
state)
Pre-wired Approx. 85 g Approx. 95 g Approx. 170 g Approx. 280 g Approx. 85 g Approx. 95 g Approx. 170 g Approx. 240 g
M12
Pre-wired
Smartclick
Connector
Approx. 55 g Approx. 70 g Approx. 105 g Approx. 220 g Approx. 55 g Approx. 70 g Approx. 105 g Approx. 170 g
Connector Approx. 40 g *6 Approx. 55 g Approx. 85 g Approx. 200 g Approx. 40 g *6 Approx. 55 g Approx. 85 g Approx. 160 g
BASIC Model