Datasheet
E2E/E2EQ NEXT Series
61
XS5 NEXT Series XS5 XS3E2E/E2EQ NEXT Series DC 2-wire E2E/E2EQ NEXT Series DC 3-wire
E2EQ NEXT Series (Spatter-resistant Triple distance model)
DC 3-wire
Shielded
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard
sensing object, and a set distance of half the sensing distance.
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
*3. Weight of the standard body-sized model.
Types Triple distance Models
Size M8 M12 M18 M30
Item Model E2EQ-X3@8 E2EQ-X6@12 E2EQ-X12@18 E2EQ-X22@30
Sensing distance 3 mm±10% 6 mm±10% 12 mm±10% 22 mm±10%
Setting distance 0 to 2.4 mm 0 to 4.8 mm 0 to 9.6 mm 0 to 16.8 mm
Differential travel 15% max. of sensing distance
Detectable object Ferrous metals (For non-ferrous metals, refer to the Engineering Data on page 68.)
Standard sensing object Iron, 9 × 9 × 1 mm Iron, 18 × 18 × 1 mm Iron, 36 × 36 × 1 mm Iron, 66 × 66 × 1 mm
Response frequency *1 1,000 Hz 800 Hz 500 Hz 200 Hz
Power supply voltage 10 to 30 VDC (including 10% ripple (p-p)), Class 2
Current consumption 1-output models: 16 mA max.
1-output models: 16 mA max.
2-output models: 20 mA max.
Output configuration B@ Models: PNP open collector, C@ Models: NPN open collector
Operation mode
(with sensing object
approaching)
1-output models (B1, C1): NO
(Normally open),
1-output models (B2, C2): NC
(Normally closed)
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C2): NC (Normally closed),
2-output models (B3, C3): NO+NC (Normally open, Normally closed)
Control
output
Load current
1-output models: 10 to 30 VDC,
Class 2, 100 mA max.
1-output models: 10 to 30 VDC, Class 2, 100 mA max.,,
2-output models: 10 to 30 VDC, Class 2, 50 mA max.
Residual
voltage
1-output models: 2 V max.
(Load current: 100 mA,
Cable length: 2 m)
1-output models: 2 V max. (Load current: 100 mA, Cable length: 2 m),
2-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m)
Indicator *2
In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit)
In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s
intervals)
Protection circuits Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection
Ambient temperature range Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance (destruction)
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance (destruction)
500 m/s
2
10 times each in X, Y,
and Z directions
1,000 m/s
2
10 times each in X, Y, and Z directions
Degree of protection
Pre-wired Models, Pre-wired Connector Models: IEC 60529: IP67, JIS C 0920 Annex 1: IP67G
Connector Models: IEC 60529: IP67
Connection method
Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m), M12 Connector Models
Weight *3
(packed
state)
Pre-wired
Models
Approx. 85 g Approx. 95 g Approx. 180 g Approx. 260 g
M12 Pre-wired
Smartclick
Connector
Approx. 55 g Approx. 70 g Approx. 115 g Approx. 200 g
Connector Approx. 40 g Approx. 55 g Approx. 95 g Approx. 180 g
Materials
Case Fluororesin coating (Base material: brass)
Sensing surface
Fluorine resin
Clamping nuts Fluororesin coating (Base material: brass)
Toothed
washers
Zinc-plated iron
Cable Vinyl chloride (PVC)
Main IO-Link functions *2
Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer
function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor
output, operating hours read-out, readout of the sensor internal temperature, and initial reset
IO-Link
Communic
ation
specificati
ons
*2
IO-Link
specification
Ver 1.1
Baud rate COM2 (38.4 kbps), COM3 (230.4 kbps)
Data length PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)
Minimum cycle
time
COM2: 2.3 ms, COM3: 0.4 ms
Accessories Instruction manual, Clamping nuts, Toothed washer
PREMIUM Model