Datasheet
E2E
8
Distance - Horizontal Repeat Accuracy
Sensing distance vs. repeat accuracy graphs
By using within the sensor installation distance, the repeat accuracy stabilizes.
This data is reference data based on a standard sensing object, and is not a guarantee of performance.
The repeat accuracy varies depending on the effects of temperature, the material and surface condition of the sensing object, and other conditions.
Minimum measurement gap
Note:
Measured at constant temperature of 2
3ºC
using an iron sensing object of size
at least as large as standard sensing object (see right).
Shielded Models
E2E-C03SR8@/E2E-S04SR8@ E2E-C04S12@/E2E-S05S12@ E2E-C05S01@
E2E-C06S02@
Unshielded Models
E2E-C03N02@/E2E-S04N02@ E2E-C04N03@/E2E-S05N03@ E2E-C06N04@
Model Minimum gap (mm)
E2E-C03S/S04S 0.3
E2E-C03N/S04N 0.6
E2E-C04S/S05S 0.4
E2E-C04N/S05N 0.9
E2E-C05S 0.3
E2E-C06S 0.6
E2E-C06N 1.2
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0 0.05 0.1 0.15 0.2
Repeat accuracy (mm)
12 VDC
24 VDC
Distance X (mm)
ON point
repeat
accuracy
@3 × 1 mm
X
1.2
1
0.8
0.6
0.4
0.2
0 0.05 0.1 0.15 0.2
12 VDC
24 VDC
Distance X (mm)
Repeat accuracy (mm)
ON point
repeat
accuracy
@4 × 1 mm
X
1.2
1
0.8
0.6
0.4
0.2
0 0.05 0.1 0.15 0.2
X
12 VDC
24 VDC
Distance X (mm)
ON point
repeat
accuracy
@5.4 × 1 mm
Repeat accuracy (mm)
2
1.8
1.6
1.4
1.2
1
0.8
0.6
0.4
0.2
0 0.05 0.1 0.15 0.2
12 VDC
24 VDC
Distance X (mm)
Repeat accuracy (mm)
ON point
repeat
accuracy
@6.5 × 1 mm
X
2
1.8
1.6
1.4
1.2
1
0.8
0.6
0.4
0.2
0 0.1 0.2 0.3 0.4 0.5
12 VDC
24 VDC
Distance X (mm)
Repeat accuracy (mm)
ON point
repeat
accuracy
@6 × 1 mm
X
3
2.5
2
1.5
1
0.5
0 0.1 0.2 0.3 0.4 0.5
12 VDC
24 VDC
Distance X (mm)
Repeat accuracy (mm)
ON point
repeat
accuracy
@9 × 1 mm
X
4
3.5
3
2.5
2
1.5
1
0.5
0 0.1 0.2 0.3 0.4 0.5
12 VDC
24 VDC
Distance X (mm)
Repeat accuracy (mm)
ON point
repeat
accuracy
@12 × 1 mm
X
30 mm
30 mm
15 mm
gap
Material: Iron
Size of test piece