Datasheet

E2E
12
Dimensions
Sensors
M8 Pre-wired Connector Models (0.3 m) (Shielded)
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Mounting Hole Dimensions
F
Pre-wired Models
(Shielded)
Dimension 3 dia. 4 dia. 5.4 dia. 6.5 dia. M4 M5
F (mm) 3.3 4.2 5.7 7 4.5 5.5
+
0
.
5
0
+
0
.
5
0
+
0
.
5
0
+
0
.
5
0
+
0
.
5
0
+
0
.
5
0
2.4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.09 mm
2
,
Insulator diameter: 0.7 mm), Standard length: 2 m
18
27.1
Operation indicators (yellow) 4 × 90°
3
0
-0.1
dia.
E2E-C03SR8-WC-@@
18.5
25.1
4
0
-0.1
dia.
Operation indicators (yellow) 4 × 90°
* 2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
0.14 mm
2
, Insulator diameter: 0.8 mm), Standard length: 2 m
Model with robot (bending-resistant) cable: 2.9-dia. vinyl-insulated round cable
with 3 conductors (Conductor cross section: 0.15 mm
2
,
Insulator diameter: 1.05 mm), Standard length: 2 m
*
E2E-C04S12-WC-@@
18.5
25.1
5.4
0
-0.1
dia.
Operation indicators (yellow) 4 × 90°
*
* 2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
0.14 mm
2
, Insulator diameter: 0.8 mm), Standard length: 2 m
Model with robot (bending-resistant) cable: 2.9-dia. vinyl-insulated round cable
with 3 conductors (Conductor cross section: 0.15 mm
2
,
Insulator diameter: 1.05 mm), Standard length: 2 m
E2E-C05S01-WC-@@
36
24.1
6.5
0
-0.1
dia.
Operation indicators (yellow) 4 × 90°
* 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
0.14 mm
2
, Insulator diameter: 0.85 mm), Standard length: 2 m
Model with robot (bending-resistant) cable: 4-dia. vinyl-insulated round cable
with 3 conductors (Conductor cross section: 0.3 mm
2
,
Insulator diameter: 1.2 mm), Standard length: 2 m
*
E2E-C06S02-WC-@@
M4 × P0.5
5
1
27.1
15.1
7
3
8.5 dia.
0.6
18
Two clamping nuts Toothed washer
2.4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.09 mm
2
,
Insulator diameter: 0.7 mm), Standard length: 2 m
Operation indicators (yellow) 4 × 90°
E2E-S04SR8-WC-@@
0.6
18.5
4
1
25.1
15.1
Operation indicators (yellow) 4 × 90°
8
10 dia.
Two clamping nuts Toothed washer
3
M5 × P0.5
* 2.9-dia. vinyl-insulated round cable with 3
conductors (Conductor cross section: 0.09 mm
2
,
Insulator diameter: 0.7 mm), Standard length: 2 m
Model with robot (bending-resistant) cable: 2.9-dia.
vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.15 mm
2
,
Insulator diameter: 1.0 mm), Standard length: 2 m
*
E2E-S05S12-WC-@@
M8 × P1
18
27.1
3
0
-0.1
dia.
Operation indicators (yellow) 4 × 90°
2.4-dia. vinyl-insulated round cable,
Standard length: 300 mm
E2E-C03SR8-CJ-@@
M8 × P1
18.5
25.1
4
0
-0.1
dia.
2.9-dia. vinyl-insulated round cable,
Standard length: 300 mm
Operation indicators (yellow) 4 × 90°
E2E-C04S12-CJ-@@
M8 × P1
24.1
36
6.5
0
-0.1
dia.
Operation indicators (yellow) 4 × 90°
4-dia. vinyl-insulated round cable,
Standard length: 300 mm
E2E-C06S02-CJ-@@
0.6
M8 × P1
18
27.1
15.1
5
1
7
8.5 dia.
3
2.4-dia. vinyl-insulated round cable,
Standard length: 300 mm
Two clamping nuts
Toothed washer
Operation indicators (yellow) 4 × 90°
M4 × P0.5
E2E-S04SR8-CJ-@@
0.6
1
18.5
25.1
15.1
4
M8 × P1
8
10 dia.
3
2.9-dia. vinyl-insulated round cable,
Standard length: 300 mm
Two clamping nuts
Toothed washer
Operation indicators (yellow) 4 × 90°
M5 × P0.5
E2E-S05S12-CJ-@@