Datasheet
E2C-EDA
9
PNP Output
Note: 1. Setting Areas for Twin-output Models
Normally open: .... ON between the thresholds for Channel 1 and Channel 2
Normally closed: .. OFF between the thresholds for Channel 1 and Channel 2
2. Timing Charts for Timer Settings (T: Set Time)
Nomenclature
Amplifier Units
Twin-output Models
(E2C-EDA11/EDA41/EDA6/EDA8/EDA0)
External-input Models
(E2C-EDA21/EDA51/EDA7/EDA9)
Model
Operation
mode
Timing chart
Mode
selector
Output circuit
E2C-EDA41
E2C-EDA8
NO (Normally
open)
NO
NC (Normally
closed)
NC
E2C-EDA51
E2C-EDA9
NO (Normally
open)
NO
NC (Normally
closed)
NC
ON delay OFF delay One shot
Ye s
No
Lit
Not lit
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between blue and black lines)
Output
transistor
Load
(relay, etc.)
Sensing
object
Orange
Load
Load
Brown
Black
Blue
Proximity
Sensor
main
circuits
Operation indicator
(orange) ch2
Control
output ch1
Control
output ch2
12 to 2
4
VDC
Operation indicator
(orange) ch1
Display
Y
es
No
Lit
Not lit
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between blue and black lines)
Output
transistor
Load
(relay, etc.)
Sensing
object
Ye s
No
Lit
Not lit
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between blue and black lines)
Output
transistor
Load
(relay, etc.)
Sensing
object
Load
Brown
Black
Blue
Proximity
Sensor
main
circuits
Control output
External
input
12 to 24
VDC
Operation
indicator (orange)
Display
Fine positioning
indicator
(orange)
Orange
Y
es
No
Lit
Not lit
ON
OFF
Operate
Reset
Operation
indicator
(orange)
(Between blue and black lines)
Output
transistor
Load
(relay, etc.)
Sensing
object
Ye s
No
ON
OFF
ON
OFF
NO
NC
T
T
Sensing
object
Ye s
No
ON
OFF
ON
OFF
NO
NC
T
T
Sensing
object
Ye s
No
ON
OFF
ON
OFF
NO
NC
T
T
Sensing
object
Displays the incident light level
or the function name.
Displays the threshold values
and function settings.
Function setting operations
UP
DOWN
MODE
Used to select the channel to
display or set.
Used to select SET or RUN mode.
ON when output is ON.
OFF when output is OFF.
ON when output is ON.
OFF when output is OFF.
Operation Indicator
for Channel 1 (Orange)
Main Display (Red)
Sub-Display (Green)
Operation Keys
Channel Selector
SET/RUN Mode Selector
Operation Indicator
for Channel 2 (Orange)
UP
DOWN
MODE
Used to select normally open
or normally closed.
Fine positioning setting
Operating Mode Selector
Fine Positioning Indicator
(Orange)
Displays the incident light level
or the function name.
Displays the threshold values
and function settings.
Function setting operations
Used to select SET or RUN mode.
ON when output is ON.
OFF when output is OFF.
Operation Indicator
(Orange)
Main Display (Red)
Sub-Display (Green)
Operation Keys
SET/RUN Mode Selector