Datasheet

8 Cylindrical Proximity Sensor E2A
DC 2-wire Models
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load
current of 50 mA max.
3. For USA and Canada: use class 2 circuit only.
Size M18 M30
Type Shielded Non-shielded Shielded Non-shielded
Item
E2A-M18@S05-D@
E2A-S18@S05-D@
E2A-M18@N10-D@
E2A-S18@N10-D@
E2A-M30
@
S10-D
@
E2A-S30
@
S10-D
@
E2A-M30
@
N18-D
@
E2A-S30
@
N18-D
@
Sensing distance 5 mm ± 10% 10 mm ± 10% 10 mm ± 10% 18 m ± 10%
Setting distance 0 to 4 mm 0 to 8 mm 0 to 8 mm 0 to 14.5 mm
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target 18x18x1 mm 30x30x1 mm 30x30x1 mm
54x54x1mm
Response frequency (See note 1.) 600 Hz 400 Hz 400 Hz 100 Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
Leakage current 0.8 mA max.
Output type DC 2 wire type
Control
output
Load current
(See note 2.)
3 to 100 mA
Residual voltage 3 V max. (under load current of 100 mA with cable length of 2 m)
Indicator (see timing chart)
NO type: Operation indicator (Yellow), Setting indicator (Red)
NC type: Operation indicator (Yellow)
Operation mode
-D1 models: NO
-D2 models: NC
Protection circuit Surget suppressor, Short circuit protection
Ambient temperature Operating: -40°C to 70°C, Storage: -40°C to 85°C (with no icing or condensation)
Temperature influence
±10% max. of sensing distance at 23°C within temperature range of -25°C to 70°C
±15% max. of sensing distance at 23°C within temperature range of -40°C to 70°C
Ambient humidity Operating: 35% to 95%, Storage: 35% to 95%
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
500 m/s
2
, 10 times each in X, Y and Z directions
Standard and listings (See note 3.)
IP67 after IEC 60529
IP69k after DIN 40050
EMC after EN60947-5-2
Connection method
Pre-wired models (standard is dia 4mm PVC cable with length = 2m).
Please see chapter 'Connectivity' for details on different cable materials and lenghts and M8 or M12
connectors.
Weight
(packaged)
Pre-wired model Approx. 160 g Approx. 280 g
short body: 280 g
long body: 370 g
Connector model Approx. 70 g Approx. 200 g
short body: 200 g
long body: 260 g
Material
Case Brass-nickel plated or stainless steel
Sensing surface PBT
Cable
Standard cable is PVC dia 4mm.
For other cable materials or diameters please refer to chapter 'Connectivity'
Clamping nut brass-nickel plated for brass models stainless steel for steel models