Datasheet

5Cylindrical Proximity Sensor E2A
Specifications
DC 3-wire Models / DC 4-wire (NO+NC)
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load
current of 100 mA max.,
3. For USA and Canada: use class 2 circuit only.
4. -B3/ -C3 NO+NC models are available in M12, M18 and M30 housings with M12 connectors, pre-wired and with cable end connectors.
Size M8 M12
Type Shielded Non-shielded Shielded Non-shielded
Item
E2A-S08@S01-@@-B1
E2A-S08@S01-@@-C1
E2A-S08@N02-@@-B1
E2A-S08@N02-@@-C1
E2A-M12
@
S02-
@@
-B
@
E2A-M12
@
S02-
@@
-C
@
E2A-S12
@
S02-
@@
-B
@
E2A-S12
@
S02-
@@
-C
@
E2A-M12
@
N05-
@@
-B
@
E2A-M12
@
N05-
@@
-C
@
E2A-S12
@
N05-
@@
-B
@
E2A-S12
@
N05-
@@
-C
@
Sensing distance 1.5 mm ± 10% 2 mm ± 10% 2 mm ± 10% 5 mm ± 10%
Setting distance 0 to 1.2 mm 0 to 1.6 mm 0 to 1.6 mm 0 to 4 mm
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target (mild steel ST37) 8×8×1 mm 8×8×1 mm 12×12×1 mm 15×15×1 mm
Response frequency (See note 1.) 2,000 Hz 1,000 Hz 1,500 Hz 800 Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
Current consumption (DC 3-wire) 10 mA max.
Output type
-B models: PNP open collector
-C models: NPN open collector
Control
output
Load current
(See note 2.)
200 mA max. (32 VDC max.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator Operation indicator (Yellow LED)
Operation mode
(with sensing object approaching)
-B1/-C1 models: NO
-B2/-C2 models: NC
-B3/ -C3 models: NO+NC
For details, refer to the timing charts. (See note 4.)
Protection circuit
Power source circuit reverse polarity protection,
Surge suppressor, Short-circuit protection
Output reverse polarity protection, Power source
circuit reverse polarity protection, Surge suppres-
sor, Short-circuit protection
Ambient air temperature Operating: -40°C to 70°C, Storage: -40°C to 85°C (with no icing or condensation)
Temperature influence (See note 2.)
±10% max. of sensing distance at 23°C within temperature range of -25°C to 70°C
±15% max. of sensing distance at 23°C within temperature range of -40°C to 70°C
Ambient humidity Operating: 35% to 95%, Storage: 35% to 95%
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
500 m/s
2
, 10 times each in X, Y and Z directions 1,000 m/s
2
, 10 times each in X, Y and Z directions
Standard and listings (See note 3.)
IP67 after IEC 60529
IP69k after DIN 40050
EMC after EN60947-5-2
Connection method
Pre-wired models (standard is dia 4mm PVC cable with length = 2m).
Please see chapter 'Connectivity' for details on different cable materials and lenghts and M8 or M12
connectors.
Weight
(packaged)
Pre-wired model Approx. 65 g Approx. 85 g
Connector model
M12 connector models: Approx. 20 g
M8 connector models: Approx. 15 g
Approx. 35 g
Material
Case Stainless steel Brass-nickel plated or stainless steel
Sensing surface PBT
Cable
Standard cable is PVC dia 4mm.
For other cable materials or diameters please refer to chapter 'Connectivity'
Clamping nut Brass-nickel plated
Brass-nickel plated for brass models stainless
steel for steel models