Datasheet

E2A Cylindrical Proximity Sensor 5
DC 3-wire Models
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load
current of 100 mA max.
3. For USA and CANADA : use class 2 circuit only.
Size M18 M30
Type Shielded Non-shielded Shielded Non-shielded Non-shielded
Item
E2A-M18@S08-@@-B1
E2A-M18@S08-@@-B2
E2A-M18@S08-@@-C1
E2A-M18@S08-@@-C2
E2A-M18@N16-@@-B1
E2A-M18@N16-@@-B2
E2A-M18@N16-@@-C1
E2A-M18@N16-@@-C2
E2A-M30@S15-@@-B1
E2A-M30@S15-@@-B2
E2A-M30@S15-@@-C1
E2A-M30@S15-@@-C2
E2A-M30KN20-@@-B1
E2A-M30KN20-@@-B2
E2A-M30KN20-@@-C1
E2A-M30KN20-@@-C2
E2A-M30LN30-@@-B1
E2A-M30LN30-@@-B2
E2A-M30LN30-@@-C1
E2A-M30LN30-@@-C2
Sensing distance 8 mm±10% 16 mm±10% 15 mm±10% 20 mm±10% 30 mm±10%
Setting distance 0 to 6.4 mm 0 to 12.8 mm 0 to 12 mm 0 to 16 mm 0 to 24 mm
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target
(mild steel ST37)
24×24×1 mm 48×48×1 mm 45×45×1 mm 60×60×1 mm 90×90×1 mm
Response frequency
(See note 1.)
500 Hz 400 Hz 250 Hz 100 Hz 100 Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
Current consumption (DC
3-wire)
10 mA max.
Output type -B models: PNP open collector
-C models: NPN open collector
Control
output
Load current (See
note 2.)
200 mA max. (32 VDC max.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator Operation indicator (Yellow LED)
Operation mode
(with sensing object ap-
proaching)
-B1/-C1 models: NO
-B2/-C2 models: NC
For details, refer to the timing charts.
Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit
protection
Ambient air temperature Operating: 40°C to 70°C, Storage: 40°C to 85°C (with no icing or condensation)
Temperature influence (See
note 2.)
±10% max. of sensing distance at 23°C within temperature range of 25°C to 70°C
±
15% max. of sensing distance at 23°C within
temperature range of 40°C to 70°C
Amb
ient humidity Operating: 35% to 95%, Storage: 35% to 95%
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
1,000 m/s
2
, 10 times each in X, Y and Z directions
Standard and listings
(See note 3.)
IEC60529: IP67, Degree of protection
EN60947-5-2: EMC
Connection method -WP models: Pre-wired models (Standard length: 2 m)
-M1 models: M12 4-pin connector models
-M5 models: M8 3-pin connector models
Weight
(pack-
aged)
Pre-wired model Approx. 160 g Approx. 280 g Approx. 280 g Approx. 370 g
M12 connector
model
Approx. 70 g Approx. 200 g Approx. 200 g Approx. 260 g
Material Case Brass-nickel plated
Sensing surface PBT
Cable PVC
Clamping nut Brass-nickel plated