Datasheet
D4SL-N / D4SL-NSK10-LK@
24
Mounting Covers
Confirm that the seal rubber has no defects before use. If the seal
rubber is displaced or raised, or has foreign particles adhered to it, the
sealing capability of the seal rubber will be adversely affected.
Hinged Door
• If the Switch is mounted too close to the hinge, the force imposed
on the lock will be much larger than for locations far from the hinge
and the lock may be damaged. Mount the Switch close to the
handle.
Mounting
Appropriate Tightening Torque
Loose screws may result in malfunction. Be sure to tighten each
screw of the Switch properly.
Switch and Operation Key Mounting
• Mount the Switch and Operation Key securely to the applicable
tightening torque with M4 screws. Always use washers.
• The switch can be fastened more firmly by a stud (4 mm dia., 1.5
mm max height) inserted from back side at the hole of the switch.
• Do not impose excessive force on the key top while the operation
key is inserted into the switch body or drop the switch with the
operation key inserted to avoid the deformation of the key or the
breakage of the switch body.
• Do not use the operation key other than dedicated OMRON's
(D4SL-NK@). Otherwise switch may be damaged.
• Do not use the operation key D4SL-K@. A lock will not be closed
and a machine will not be activated.
• Be sure that the operation key can be inserted properly to key hole
with a tolerance of ±0.8 mm.
• Insert the operation key into the key hole according to the specified
“operation key insertion radius in horizontal direction”.
• When mounting at the side of switch body, mount the switch with 3
points including the head.
• Attach cap heads to any operation key holes that are not being
used.
Securing the Door
When the door is closed (with the
Operation Key inserted), the Operation
Key may exceed the set zone because
of, for example, the door's own weight,
machine vibration, or the door cushion
rubber.
Secure the door with a stopper (hook)
so that the Operation Key remains
within the set zone.
Spacer
Do not remove a spacer. Rotate the spacer in accordance with the
Switch mounting direction. Use of the Switch without spacer will
reduce the lock strength.
Wiring
• DC solenoids have polarity. (E1: +, E2: −) Confirm terminal polarity
before wiring.
• The current of the 24 VDC solenoid is different from when it is first
turned ON as to when it is in operation. To take into account
possible voltage drops, it is important to apply a rated operation
voltage.
• To enable the 24 VDC solenoid, it is necessary to select the
appropriate power supply capacity.
• The ON and OFF contact operation will not engage
simultaneously.
Be sure to confirm operation under actual operating conditions.
• If a lock is required for safety, design the system so that the closing
of the NC contacts on both the door open/closed detection switch
and the lock monitor switch is detected.
Cover mounting
screw
0.4 to 0.5 N·m
Operation Key
mounting screw
2.4 to 2.8 N·m (D4SL-NK@ and -NK@S)
0.75 to 1.15 N·m (D4SL-NK@G)
Switch mounting
screw
0.75 to 1.15 N·m
Cable gland
1.8 to 2.2 N·m (except 1/2-14NPT)
1.4 to 1.8 N·m (1/2-14NPT)
Terminal screw
* Terminal block type
only
0.5 to 0.6 N·m (D4SL-N@@@@-@@)
15
±
0.1
40
±
0.1
10
±0.1
Two, M4
12
±
0.1
or 20
±0.1
Two, M4
Two, M4
Two, M4
38.7
±0.1
Three, M4
22
±0.1
41.7
±0.15
41.7
±0.15
Front D4SL-NK1/-NK2
D4SL-NK1G/-NK2G
D4SL-NK3
Side
Two, M 4
Stud: 4
±0.1
dia., height: 1.5 max.
Stud: 4
±0.1
dia., height: 1.5 max.
22
±0.1
D4SL-NK5
41
±
0.1
or 43
±
0.1
Switch mounting Operation Key mounting
Set zone *
(0.5 to 3 mm)
Operation key
* If you use the D4SL-NK5 with the
front key hole oriented in the
direction shown in the right diagram,
the set zone will be 2.1 to 3.0 mm.
Spacer
Mounting side