Datasheet
D4SL-N / D4SL-NSK10-LK@
24
Hinged Door
• If the Switch is mounted too close to the hinge, the force imposed 
on the lock will be much larger than for locations far from the hinge 
and the lock may be damaged. Mount the Switch close to the 
handle.
Mounting
Appropriate Tightening Torque
Loose screws may result in malfunction. Tighten the screws to the 
specified torques.
Switch and Operation Key Mounting
• Mount the Switch and Operation Key securely to the applicable 
tightening torque with M4 screws. Always use washers.
• The switch can be fastened more firmly by a stud (4 mm dia., 1.5 
mm max height) inserted from back side at the hole of the switch.
• Do not impose excessive force on the key top while the operation 
key is inserted into the switch body or drop the switch with the 
operation key inserted to avoid the deformation of the key or the 
breakage of the switch body.
• Do not use the operation key other than dedicated OMRON's 
(D4SL-NK@). Otherwise switch may be damaged.
• Do not use the operation key D4SL-K@. A lock will not be closed 
and a machine will not be activated.
• Be sure that the operation key can be inserted properly to key hole 
with a tolerance of ±0.8 mm.
• Insert the operation key into the key hole according to the specified 
“operation key insertion radius in horizontal direction”.
• When mounting at the side of switch body, mount the switch with 3 
points including the head. 
• Attach cap heads to any operation key holes that are not being 
used.
Securing the Door
When the door is closed (with the 
Operation Key inserted), the Operation 
Key may exceed the set zone because 
of, for example, the door's own weight, 
machine vibration, or the door cushion 
rubber.
Secure the door with a stopper (hook) 
so that the Operation Key remains 
within the set zone.
Spacer
Do not remove a spacer. Rotate the spacer in accordance with the 
Switch mounting direction. Use of the Switch without spacer will 
reduce the lock strength.
Wiring
Circuit Connection Example
• Direct opening contacts used as safety-circuit inputs are indicated 
with the   mark.
• DC solenoids have polarity. (E1: +, E2: −) Confirm terminal polarity 
before wiring.
• The current of the 24 VDC solenoid is different from when it is first 
turned ON as to when it is in operation. To take into account 
possible voltage drops, it is important to apply a rated operation 
voltage.
• To enable the 24 VDC solenoid, it is necessary to select the 
appropriate power supply capacity.
• The ON and OFF contact operation will not engage 
simultaneously.
Be sure to confirm operation under actual operating conditions.
• If a lock is required for safety, design the system so that the closing 
of the NC contacts on both the door open/closed detection switch 
and the lock monitor switch is detected.
(D4SL-N@N@@-D@)
Contacts 12 and 41 and contacts 22 and 51 are internally connected.
(D4SL-N@SF@-@)
There is no internal connection, so connect contacts 22 and 42 or 21 
and 42 externally.
Cover mounting 
screw
0.4 to 0.5 N•m
Operation Key 
mounting screw
2.4 to 2.8 N•m (D4SL-NK@ and -NK@S)
0.75 to 1.15 N•m (D4SL-NK@G)
Switch mounting 
screw
0.75 to 1.15 N•m
Connector
1.8 to 2.2 N•m (except 1/2-14NPT)
1.4 to 1.8 N•m (1/2-14NPT)
Terminal screw
* Terminal block type 
only
0.5 to 0.6 N•m (D4SL-N@@@@-@@)
15
±
0.1
40
±
0.1
10
±0.1
Two,   M4
12
±
0.1
 or 20
±0.1
Two,   M4
Two, M4
Two, M4
38.7
±0.1
Three, M4
22
±0.1
41.7
±0.15
41.7
±0.15
Front D4SL-NK1/-NK2
D4SL-NK1G/-NK2G
D4SL-NK3
Side
Two, M4
4
±0.1
 dia. 1.5 max.
22
±0.1
4
±0.1
 dia. 1.5 max.
D4SL-NK5
41
±
0.1
 or 43
±
0.1
Switch mounting Operation Key mounting
Set zone
(0.5 to 3 mm)
Operation key
Spacer
Mounting side
E1
(+)
E2
(−)
To safety circuit
To control circuit
11
21
33
Lock monitor
switch
9
10
LED
41
51
63
42
52
64
1
2
3
4
5
67
8
12
22
34
To control circuit
To safety circuit
Door open/
closed detection
switch
E1
(+)
E2
(−)
To control circuit
21
41
33
Lock monitor
switch
9
10
63
42
22
64
1
2
3
4
5
67
8
34
To control circuit
Door open/
closed detection
switch
To safety circuit
To safety circuit
Shortcircuit