Datasheet
G-135D4NS
Nomenclature
Structure
D4NS-@A@, D4NS-@B@, D4NS-@E@
D4NS-@C@, D4NS-@D@, D4NS-@F@
Contact Form (Diagrams Show State with Key Inserted)
Note: MBB (Make Before Break) contacts have an overlapping structure, so that before the normally closed contact (NC) opens, the normally open
contact (NO) closes.
Model Contact Contact form Operating pattern Remarks
D4NS-@A@ 1NC/1NO
D4NS-@B@ 2NC
D4NS-@C@ 2NC/1NO
D4NS-@D@ 3NC
D4NS-@E@ 1NC/1NO MBB
D4NS-@F@ 2NC/1NO MBB
Terminal 12
Terminal 32 (34)
Terminal 31 (33) Terminal 32 (34)Terminal 31 (33)
Terminal 22
Terminal 12
Terminal 21
Terminal 11
Terminal 11
Note: The 2-conduit models have the same terminal arrangement.
Operation 
key hole
Head
The head can be mounted 
in four directions. 
Sealing properties
The switch casing ensures IP67 
(except the keyhole, which 
ensures IP00). Use the D4NS in 
places where the keyhole is free 
from oil, water, and metal chips.
11
33
12
34
11-12
33-34
ON
Extraction 
completion 
position
Operation 
Key insertion 
completion 
position
Stroke
Only NC contacts 11-12 have an 
approved direct opening 
mechanism.
The terminals 11-12 and 33-34 
can be used as unlike poles.
11
31
12
32
11-12
31-32
O
N
Extraction 
completion 
position
Operation 
Key insertion 
completion 
p
osition
Stroke
Only NC contacts 11-12 and 
31-32 have an approved 
direct opening mechanism.
The terminals 11-12 and 31-32 
can be used as unlike poles.
33 34
11
21
12
22
21-22
33-34
11-12
O
N
Extraction 
completion 
position
Operation 
Key insertion 
completion 
position
Stroke
Only NC contacts 11-12 and 
21-22 have an approved 
direct opening mechanism.
The terminals 11-12, 21-22, and 
33-34 can be used as unlike 
poles.
11
21
12
22
31 32
11-12
21-22
31-32
ON
Extraction 
completion 
position
Operation 
Key insertion 
completion 
p
osition
Stroke
Only NC contacts 11-12, 21-22, 
and 31-32 have an approved di-
rect opening mechanism.
The terminals 11-12, 21-22, and 
31-32 can be used as unlike 
poles.
11
33
12
34
11-12
33-34
ON
Extraction 
completion 
position
Operation 
Key insertion 
completion 
position
Stroke
Only NC contacts 11-12 have an 
approved direct opening 
mechanism.
The terminals 11-12 and 33-34 
can be used as unlike poles.
33 34
11
21
12
22
11-12
21-22
33-34
ON
Extraction 
completion 
position
Operation 
Key insertion 
completion 
p
osition
Stroke
Only NC contacts 11-12 and 
21-22 have an approved direct 
opening mechanism.
The terminals 11-12, 21-22 and 