Datasheet
D4NL
5
Operation Keys
Specifications
Standards and EC Directives
Conforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EN ISO 14119
• EN 60204-1
• GS-ET-19
Certified Standards
Standard type
*1. Certification for CSA C22.2 No. 14 is authorized by the UL mark.
*2. Only certain models have been certified.
Metallic release key type
Certified Standard Ratings
TÜV (EN60947-5-1), CCC (GB14048.5)
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a
short-circuit protection device. This fuse is not built into the
Switch.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Q300
Solenoid Coil Characteristics
Indicator Characteristics
Type Model
D4DS-K1
D4DS-K2
D4DS-K3
D4DS-K5
Horizontal mounting
Vertical mounting
Adjustable mounting
(Horizontal)
Adjustable mounting
(Horizontal/Vertical)
Certification body Standard File No.
TÜV SÜD
EN60947-5-1
(certified direct opening)
Consult your
OMRON
representative for
details.
UL *1 UL508, CSA C22.2 No.14 E76675
CQC (CCC) GB14048.5
2003010305064267
KOSHA *2 EN60947-5-1
Consult your
OMRON
representative for
details.
Certification body Standard File No.
TÜV SÜD
EN60947-5-1
(certified direct opening)
Consult your
OMRON
representative for
details.
KOSHA EN60947-5-1
Consult your
OMRON
representative for
details.
Item
Utilization
category
AC-15 DC-13
Rated operating current (Ie) 3 A 0.27 A
Rated operating voltage (Ue) 240 V 250 V
Rated
voltage
Carry current
Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC
10 A
60 6
7,200 720
240 VAC 30 3
Rated
voltage
Carry current
Current (A) Volt-amperes (VA)
Make Break Make Break
125 VDC
2.5 A
0.55 0.55
69 69
250 VDC 0.27 0.27
Item Type 24 VDC 110 VAC
Rated operating voltage
(100% ED)
24 VDC
110 VAC ±10%
Current
consumption
Approx. 200 mA Approx. 50 mA
Insulation Class B (130°C max.)
Item Type LED
Rated voltage 10 to 115 VAC/VDC
Current leakage Approx. 1 mA
Color (LED) Orange
+10%