Datasheet

G-270 Safety Sensors / Components
Characteristics
Note: 1. The above values are initial values.
2. Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity. Doing so may result in rough-
ening of the contact surface and contact reliability may be lost.
3. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are suffi-
cient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do
not use the D4N-@R in places where foreign material such as dust, dirt, oil, water, or chemicals may penetrate through the head. Other-
wise, premature wear, Switch damage or malfunctioning may occur.
4. The durability is for an ambient temperature of 5° C to 35° C and an ambient humidity of 40% to 70%. For more details, consult your
OMRON representative.
5. If the ambient temperature is greater than 35° C, do not pass the 3-A, 250-VAC load through more than 2 circuits.
6. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the ac-
tual load beforehand.
Degree of protection (See note 3.) IP67 (EN60947-5-1)
Durability
(See note 4.)
Mechanical 1,000,000 operations min.
Electrical 500,000 operations min. for a resistive load of 3 A at 250 VAC (See note 5.)
300,000 operations min. for a resistive load of 10 A at 250 VAC
Operating speed 1 mm/s to 0.5 m/s (D4N-1A20R)
Operating frequency 30 operations/minute max.
Contact resistance 25 m max.
Minimum applicable load (See note 6.) Resistive load of 1 mA at 5 VDC (N-level reference value)
Rated insulation voltage (U
i
) 300 V
Protection against electric shock Class II (double insulation)
Pollution degree (operating environment) Level 3 (EN60947-5-1)
Impulse withstand voltage (EN60947-5-1) Between terminals of the same polarity: 2.5 kV
Between terminals of different polarities: 4 kV
Between other terminals and uncharged metallic parts: 6 kV
Insulation resistance 100 M min.
Contact gap Snap-action: 2 x 0.5 mm min
Slow-action: 2 x 2 mm min
Vibration resistance Malfunction 10 to 55 Hz, 0.75-mm single amplitude
Shock resistance Destruction
1,000 m/s
2
Malfunction
300 m/s
2
Conditional short-circuit current 100 A (EN60947-5-1)
Rated open thermal current (I
th
) 10 A (EN60947-5-1)
Ambient temperature Operating: 30° C to 70° C with no icing
Ambient humidity Operating: 95% max.
Weight Approx. 92 g (D4N-1A20R)
F502-EN2-04.book Seite 270 Dienstag, 26. Juli 2005 5:48 17