Datasheet
G-224 Safety Sensors / Components
General-purpose Switches with Three Contacts and MBB Contacts
Note: 1. It is recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North
American countries.
2. Mechanically speaking, these models are basic limit switches.
Specifications
Standards and EC Directives
• Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN50047
EN1088 (slow-action models only)
GS-ET-15
Approved Standards
Note: Approval for CSA C22.2 No. 14 is authorized by the UL mark.
CCC (China Compulsory Certification) Mark
Approved Standard Ratings
TÜV (EN60947-5-1)
Note: Use a 10-A fuse type gI or gG that conforms to IEC269 as a short-circuit
protection device. This fuse is not built into the Switch.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Q300
Actuator Conduit size Built-in switch mechanism
Direct
opening
2NC/1NO
(Slow-action)
Direct
opening
3NC
(Slow-action)
Direct
opening
1NC/1NO
MBB
(Slow-action)
Direct
opening
2NC/1NO
MBB
(Slow-action)
Fork lever lock
(right operation)
1-conduit G1/2 --- D4N-2CRE --- D4N-2DRE --- D4N-2ERE --- D4N-2FRE
1/2-14NPT D4N-3CRE D4N-3DRE D4N-3ERE D4N-3FRE
M20 D4N-4CRE D4N-4DRE D4N-4ERE D4N-4FRE
2-conduit G1/2 --- D4N-6CRE --- D4N-6DRE --- D4N-6ERE --- D4N-6FRE
M20 D4N-8CRE D4N-8DRE D4N-8ERE D4N-8FRE
Fork lever lock
(left operation)
1-conduit G1/2 --- D4N-2CLE --- D4N-2DLE --- D4N-2ELE --- D4N-2FLE
1/2-14NPT D4N-3CLE D4N-3DLE D4N-3ELE D4N-3FLE
M20 D4N-4CLE D4N-4DLE D4N-4ELE D4N-4FLE
2-conduit G1/2 --- D4N-6CLE --- D4N-6DLE --- D4N-6ELE --- D4N-6FLE
M20 D4N-8CLE D4N-8DLE D4N-8ELE D4N-8FLE
Cat whisker 1-conduit G1/2 --- --- --- D4N-2D80 --- --- --- ---
1/2-14NPT D4N-3D80
M20 D4N-4D80
2-conduit G1/2 --- --- D4N-6D80 --- ---
M20 D4N-8D80
Plastic rod 1-conduit G1/2 --- --- D4N-2D87 --- ---
1/2-14NPT D4N-3D87
M20 D4N-4D87
2-conduit G1/2 --- --- D4N-6D87 --- ---
M20 D4N-8D87
Agency Standard File No.
TÜV Product
Service
EN60947-5-1 (approved
direct opening)
B03 11 39656
061
UL (See note.) UL508, CSA C22.2 No.14 E76675
Agency Standard File No.
CQC GB14048.5 Under applica-
tion
Item
Utilization
category
AC-15 DC-13
Rated operating current (I
e
) 3 A 0.27 A
Rated operating voltage (U
e
) 240 V 250 V
Rated
voltage
Carry current Current Volt-amperes
Make Break Make Break
120 VAC 10 A 60 A 6 A 7,200 VA 720 VA
240 VAC 30 A 3 A
Rated
voltage
Carry current Current Volt-amperes
Make Break Make Break
125 VDC 2.5 A 0.55 A 0.55 A 69 VA 69 VA
250 VDC 0.27 A 0.27 A
WARNING
@
Do not use general purpose switch models for applications that
require form lock for safety reasons