Datasheet

G-224 Safety Sensors / Components
General-purpose Switches with Three Contacts and MBB Contacts
Note: 1. It is recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North
American countries.
2. Mechanically speaking, these models are basic limit switches.
Specifications
Standards and EC Directives
Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN50047
EN1088 (slow-action models only)
GS-ET-15
Approved Standards
Note: Approval for CSA C22.2 No. 14 is authorized by the UL mark.
CCC (China Compulsory Certification) Mark
Approved Standard Ratings
TÜV (EN60947-5-1)
Note: Use a 10-A fuse type gI or gG that conforms to IEC269 as a short-circuit
protection device. This fuse is not built into the Switch.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Q300
Actuator Conduit size Built-in switch mechanism
Direct
opening
2NC/1NO
(Slow-action)
Direct
opening
3NC
(Slow-action)
Direct
opening
1NC/1NO
MBB
(Slow-action)
Direct
opening
2NC/1NO
MBB
(Slow-action)
Fork lever lock
(right operation)
1-conduit G1/2 --- D4N-2CRE --- D4N-2DRE --- D4N-2ERE --- D4N-2FRE
1/2-14NPT D4N-3CRE D4N-3DRE D4N-3ERE D4N-3FRE
M20 D4N-4CRE D4N-4DRE D4N-4ERE D4N-4FRE
2-conduit G1/2 --- D4N-6CRE --- D4N-6DRE --- D4N-6ERE --- D4N-6FRE
M20 D4N-8CRE D4N-8DRE D4N-8ERE D4N-8FRE
Fork lever lock
(left operation)
1-conduit G1/2 --- D4N-2CLE --- D4N-2DLE --- D4N-2ELE --- D4N-2FLE
1/2-14NPT D4N-3CLE D4N-3DLE D4N-3ELE D4N-3FLE
M20 D4N-4CLE D4N-4DLE D4N-4ELE D4N-4FLE
2-conduit G1/2 --- D4N-6CLE --- D4N-6DLE --- D4N-6ELE --- D4N-6FLE
M20 D4N-8CLE D4N-8DLE D4N-8ELE D4N-8FLE
Cat whisker 1-conduit G1/2 --- --- --- D4N-2D80 --- --- --- ---
1/2-14NPT D4N-3D80
M20 D4N-4D80
2-conduit G1/2 --- --- D4N-6D80 --- ---
M20 D4N-8D80
Plastic rod 1-conduit G1/2 --- --- D4N-2D87 --- ---
1/2-14NPT D4N-3D87
M20 D4N-4D87
2-conduit G1/2 --- --- D4N-6D87 --- ---
M20 D4N-8D87
Agency Standard File No.
TÜV Product
Service
EN60947-5-1 (approved
direct opening)
B03 11 39656
061
UL (See note.) UL508, CSA C22.2 No.14 E76675
Agency Standard File No.
CQC GB14048.5 Under applica-
tion
Item
Utilization
category
AC-15 DC-13
Rated operating current (I
e
) 3 A 0.27 A
Rated operating voltage (U
e
) 240 V 250 V
Rated
voltage
Carry current Current Volt-amperes
Make Break Make Break
120 VAC 10 A 60 A 6 A 7,200 VA 720 VA
240 VAC 30 A 3 A
Rated
voltage
Carry current Current Volt-amperes
Make Break Make Break
125 VDC 2.5 A 0.55 A 0.55 A 69 VA 69 VA
250 VDC 0.27 A 0.27 A
WARNING
@
Do not use general purpose switch models for applications that
require form lock for safety reasons