Datasheet

D4MC
D4MC
7
Precautions
Correct Use
Operating Method
Excessive dog angle, operating speed, or overtravel (OT) may
damage the actuator. Check that OT has a sufficient margin. The
actual
OT should be rated OT x 0.7 to 1.
Handling
Do not expose the Switch to water exceeding 60°C or use it in
steam.
Do
not use the Switch in oil or water
.
An 8.5- to 10.5-dia. cable can be applied
as seal rubber for the
lead
wire outlet. (Use two- or three-core cable
of VCT1.25 mm
2
.)
When detaching the Terminal Protective Cover, insert a
screwdriver and apply a force in the opening direction. Do not
use excess force to remove the cover. Doing so may cause
deformation
in the fitting section and reduce the holding force.
Screwdriver
T
erminal Protective Cover
When
mounting
the T
erminal Protective Cover to the case, align the
cover
on the case and then press the cover down to mount
it firmly
. If
the
cover is pressed down in an inclined position, rubber packing will
deform
and thus af
fect the sealing capability
.
Rubber packing Rubber packing
Mounting
When
mounting the Switch with screws on
a side surface, fasten the
Switch with M4 screws and use washers, spring washers, etc., to
ensure
secure mounting.
Mounting Holes
T
wo, 4.3-dia. or M4 screw holes
When mounting the Panel Mount-type Switch (DCMC-5000,
D4MC5020, or D4MC5040) with screws on a side surface,
remove
the hexagonal nuts from the actuator
.
When
mounting the
panel mount type on a panel, be careful not
to tighten to an excessive torque. Tightening the screws to a
torque
exceeding 4.91 N
S
m will cause the plunger to fail.
Mounting Hole Dimensions
12.5
+0.2
0
dia. 12.5
+0.2
0
dia.
5
+0.2
0
13
+0.2
0
D4MC-5000
D4MC-5020, D4MC5040
Correct Tightening Torque
A loose screw may cause malfunctions. Be sure to tighten each
screw
to the proper tightening torque as shown in the table.
No. Type Torque
1 T
erminal screw
0.78 to 1.18 N
S
m
2
Panel mounting screw
2.94 to 4.92 N
S
m
3
Side mounting screw
1.18 to 1.47 N
S
m
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To
convert millimeters into inches, multiply by 0.03937. T
o convert grams into ounces, multiply by 0.03527.
Cat. No. C027-E1-7