Datasheet
G-260 Safety Sensors / Components
Standards and EC Directives
• Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN60204-1
EN1088
EN50047
EN81
EN115
GS-ET-15
JIS C 8201-5-1
Approved Standards
Note: 1. Contact your Omron sales representative.
2. Approval has been obtained for CSA C22.2 No. 14
under UL.
Ordering Information
Model Number Legend
List of Models
Prefered items
Specifications
Approved Standard Ratings
TÜV (EN60947-5-1)
Note: Use a 10-A fuse type gI or gG that conforms to IEC269 as a
short-circuit protection device.
UL/CSA (UL508, CSA C22.2 No. 14)
C300
Q300
Agency Standards File No.
TÜV Product
service
EN60947-5-1
(Direct opening: approved)
(See note 1.)
UL (See note 2.) UL508
CSA C22.2 No.14
E76675
D4F-@@-@@
1 2 3 4
1. Built-in Switch
1: 1NC/1NO (slow-action)
2: 2NC (slow-action)
3: 2NC/2NO (slow-action)
4: 4NC (slow-action)
2. Actuator
02: Roller plunger
(Metallic roller)
20: Roller lever
(Metallic lever, resin roller)
3. Cable Length
1: 1 m
3: 3 m
5: 5 m
4. Pull-outing direction of cable
R: Horizontal
D: Vertical
Actuator Cable
length
Cable
direction
Built-in switch
1NC/1NO
(slow-action)
2NC
(slow-action)
2NC/2NO
(slow-action)
4NC
(slow-action)
Roller lever (Me-
tallic lever, resin
roller)
1 m Horizontal
D4F-120-1R D4F-220-1R D4F-320-1R D4F-420-1R
Vertical
D4F-120-1D D4F-220-1D D4F-320-1D D4F-420-1D
3 m Horizontal
D4F-120-3R D4F-220-3R D4F-320-3R D4F-420-3R
Vertical
D4F-120-3D D4F-220-3D D4F-320-3D D4F-420-3D
5 m Horizontal
D4F-120-5R D4F-220-5R D4F-320-5R D4F-420-5R
Vertical
D4F-120-5D D4F-220-5D D4F-320-5D D4F-420-5D
Roller plunger
(Metallic roller)
1 m Horizontal
D4F-102-1R D4F-202-1R D4F-302-1R D4F-402-1R
Vertical
D4F-102-1D D4F-202-1D D4F-302-1D D4F-402-1D
3 m Horizontal
D4F-102-3R D4F-202-3R D4F-302-3R D4F-402-3R
Vertical
D4F-102-3D D4F-202-3D D4F-302-3D D4F-402-3D
5 m Horizontal D4F-102-5R D4F-202-5R D4F-302-5R D4F-402-5R
Vertical D4F-102-5D D4F-202-5D D4F-302-5D D4F-402-5D
Item Utilization category AC-15 DC-13
Rated operating current (Ie) 0.75 A 0.27 A
Rated operating voltage (Ue) 240 V 250 V
Rated
voltage
Carry
current
Current Volt-amperes
Make Break Make Break
120 VAC 2.5 A 15 A 1.5 A 1,800 VA 180 VA
240 VAC 7.5 A 0.75 A
Rated
voltage
Carry
current
Current Volt-amperes
Make Break Make Break
125 VDC 2.5 A 0.55 A 0.55 A 69 VA 69 VA
250 VDC 0.27 A 0.27 A
F502-EN2-04.book Seite 260 Dienstag, 26. Juli 2005 5:48 17