Datasheet

D4BS
G-147D4BS
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
3. The conduit thread varies with the model as follows:.
Switches
Operation Keys
Conduit thread Model
Pg 13.5 D4BS-1##S, D4BS-5##S
G1/2 D4BS-2##S, D4BS-6##S
M20 D4BS-4##S, D4BS-8##S
31.4
17
66.4
50.9
5.3
(110)
51
28.5
57
63
7
41
16
34.5
75.4
71.4
17.2
35.7
38.3
35
17
31.4
7
7.3
5.3
8
(111.5)
41
16
34.5
77
15
43
60±0.2
30±0.1
40
+1
0
31.5
Two caps
Cover
Two, 5
+0.15
dia. holes (6 mm deep)
-0
Cover
1-conduit
3-conduit
Red
Red
D4BS-1##S
D4BS-2##S
D4BS-4##S
D4BS-5##S
D4BS-6##S
D4BS-8##S
Two, 5.3 dia.
mounting holes
Two, M4 cover
clamping screws
Four, M3.5 head
clamping screws
Four, M3.5 head
clamping screws
Six, 5.3 dia.
mounting holes
Four, M3.5 x 10 cover
clamping screws
D4BS-1##S: Pg13.5
D4BS-2##S: G1/2
D4BS-4##S: 1/2-14NPT
D4BS-5##S: 3-Pg13.5
D4BS-6##S: 3-G1/2
D4BS-8##S: 3-1/2-14NPT
30±0.2
19.61 N max.
19.61 N max.
10±5 mm
19.61 N min.
20 mm min.
D4BS-1##S
D4BS-2##S
D4BS-4##S
Operating
characteristics
Key insertion force
Key extraction force
Pretravel (PT)
Direct opening force
Direct opening stroke
19.61 N max.
19.61 N max.
10±5 mm
19.61 N min.
20 mm min.
D4BS-5##S
D4BS-6##S
D4BS-8##S
Operating
characteristics
Key insertion force
Key extraction force
Pretravel (PT)
Direct opening force
Direct opening stroke
40
26
40
2012
(80.7)
36
5
11.4
30
34.6
17.5
2.5
(37.8)
30±0.15
15
15
53.7
13
26
11.4
5
2.5
36
5.3
12 7.5
20
40±0.15
52.4
26 15
40.7
78.7
36
7.3 15
5.3 5.3
20
7.5
2.5
5
11.4
20±0.15
12
19.5±0.15
4 dia. M4 Allen-head bolt
5.3 ¥ 7.3 mounting long hole
4 dia.
4 dia.
Two, 2.65R
D4BS-K1
D4BS-K2
D4BS-K3
Black
Black
Black
Red
5.3 dia.
mounting hole
F502-EN2-04.book Seite 147 Dienstag, 26. Juli 2005 5:48 17