Datasheet
G-144 Safety Sensors / Components
Operation Keys (Order Separately)
Specifications
Approved Standards Standards and EC Directives
Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN50041
EN1088
Approved Standard Ratings
TÜV (EN60947-5-1)
Note: Use a 10-A fuse type a gI or gG that conforms to IEC269 as a short-circuit protection device.
UL/CSA (UL508, CSA C22.2 No. 14)
A600
Type Model
D4BS-K1
D4BS-K2
D4BS-K3
Horizontal mounting
Vertical mounting
Adjustable mounting
(Horizontal)
Agency Standard File No.
TÜV Rheinland EN60947-5-1
UL UL508 E76675
CSA CSA C22.2 No. 14 LR45746
BIA GS-ET-15 9303323
SUVA SUVA E6187.d
R9351022
(Direct open-
ing: approved)
Utilization category AC-15
Rated operating current (Ie) 2 A
Rated operating voltage (Ue) 400 V
Rated voltage Carry current
Current Volt-amperes
Make Break Make Break
120 VAC
10 A
60 A 6 A
7,200 VA 720 VA
240 VAC
30 A 3 A
480 VAC
15 A 1.5 A
600 VAC
12 A 1.2 A
F502-EN2-04.book Seite 144 Dienstag, 26. Juli 2005 5:48 17