Datasheet
G-188 Safety Sensors / Components
Solenoid Coil Characteristics
Indicator Characteristics
Contact Form (Diagrams Show State with Key Inserted and Lock Engaged)
Note: The EN-approved direct opening mechanism is indicated by on the switch.
Item 24-VDC mechanical lock models 110-VAC mechanical lock models 24-VAC solenoid lock models
Rated operating voltage 24 VDC
+10%
/
–15%
(100% ED) 110 VAC ±10% (50/60 Hz) 24 VDC
+10%
/
–15%
(100% ED)
Current consumption Approx. 300 mA Approx. 98 mA Approx. 300 mA
Insulation Class F (130°C or less)
Item LED
Rated voltage 10 to 115 VAC/VDC
Current leakage Approx. 1 mA
Color (LED) Orange, green
Model Contact Diagram Remarks
D4BL-#C##-#
1NC/
1NO+1NC
o
D4BL-#D##-# 2NC+1NC
31
32 11
12
24
23
Stroke
ON
Lock position
Operation Key
insertion comple-
tion position
Extraction
completion
position
Only NC contacts 11-12
and 31-32 have an
approved direct
opening mechanism.
The terminals 11-12
and 23-24 can be
used as unlike poles.
12
22
113231
21
Stroke
ON
Lock position
Operation Key
insertion comple-
tion position
Extraction
completion
position
NC contacts 11-12,
21-22, and 31-32
have an approved
direct opening
mechanism.
The terminals 11-12
and 21-22 can be
used as unlike poles.
F502-EN2-04.book Seite 188 Dienstag, 26. Juli 2005 5:48 17