Datasheet
D40A/G9SX-NS
14
Non-contact Door Switch and Non-contact Door Switch Controller Wiring
Example: Wiring a Single Switch
* The auxiliary output load current must be 10 mA max.
Example: Wiring Multiple Switches
Connect Up to 30 Non-contact Door Switches
Wiring of Inputs and Outputs
White
G9SX-NS202-@
G9SX-NSA222-T03-@
Auxiliary output load *
D40A-1C@
D1
D2 D3 D4 A2
Black
Brown
Blue
Ye l l o w
G9SX-NS202-@
G9SX-NSA222-T03-@
White
D1
D2 D3 D4
White
White
Black
Black
Black
Brown
Brown
Brown
Blue
Blue
Blue
Signal name Wire color Description of operation
Non-contact Door Switch
power supply input
Brown
Supplies power to the D40A.
Connect to the D3 and D4 terminal of the G9SX-NS@.
Blue
Non-contact Door Switch input White
Inputs signals from the G9SX-NS@.
The Non-contact Door Switch input must be ON as a required condition for the Non-contact
Door Switch output to be ON.
Non-contact Door Switch
output
Black
Turns ON and OFF according to actuator detection and the status of the Non-contact Door
Switch input.
Auxiliary output Yellow Turns ON when actuator is detected.