Datasheet

D40A
8
Specifications
Non-contact Door Switches
Ratings and Characteristics
*1. The condition of this distance are that the switch and actuator target marks are on the same axis and the sensing surfaces are exactly parallel
condition. OFF to ON distance shows the switch approaching (Point A in the engineering data graph) and ON to OFF distance shows the switch
separating away (Point B in the engineering data graph).
*2. For details on response time and operating time, refer to the catalog or manual of a safety controller to be connected.
*3. Turns ON when the actuator is approaching. The G3R series of the SSR can be driven at an auxiliary output of 10 mA. Contact your OMRON
representative for details.
*4. For details, refer to item 5 on page 33.
Engineering Data
Item Model D40A-1C@
Interlock type Type 4 (EN ISO 14119)
Coding level Low level coded (EN ISO 14119)
Operating
characteristics *2
Operating distance OFFON 5 mm min. *1
Operating distance ONOFF 15 mm max. *1
Differential travel 20% or less of operating distance at 23°C (maximum 2.5 mm)
Influence of temperature (max.) ±20% of operating distance at 23°C, within temperature range of 10 to 55°C
Repeat accuracy ±10% or less of operating distance at 23°C
Ambient operating temperature 10 to 55°C (no icing or condensation)
Ambient operating humidity 25% to 85%
Insulation resistance (between charged parts and
case)
50 MΩ max. (at 500 VDC)
Dielectric strength (between charged parts and case) 1,000 VAC for 1 min
Pollution degree 3
Electromagnetic compatibility IEC/EN 60497-5-3 compliant
Vibration resistance
10 to 55 to 10 Hz (single amplitude: 0.75 mm, double
amplitude: 1.5 mm)
Shock resistance 300 m/s
2
min.
Degree of protection IP67
Material PBT resin
Mounting method M4 screws
Terminal screw tightening torque 1 N·m
Power supply voltage 24 VDC +10%/15%
Power consumption 0.6 W max.
Auxiliary outputs *3 24 VDC, 10 mA (PNP open-collector outputs)
LED indicators Actuator not detected (red); actuator detected (yellow)
Connection cables 2 m, 5 m, 0.15m (Connector type)
Number of connectable switches 30 max. (wiring length: 100 m max.) *4
Weight Switch: approx. 145 g, actuator: approx. 20 g (D40A-1C2)
ON OFF
Unstable
range
15mm (point B) 5mm (point A)
Y-direction movement
Note: 1. The operating distance is the distance between the switch and actuator sensing surfaces.
2. The graph indicates shifting to X or Z direction from following condition that the switch and
actuator target marks are on the same axis and the sensing surfaces are exactly parallel
condition.
Dashed lines indate reference value for maximum and minimun oprating distance at abient
temperature +23°C. The solid line indicates reference values of the maximum and
minimum operating distances.
3. The operating distance may be affected by ambient metal, magnet catches, and
temperature.
X
Y
16
14
12
10
8
6
4
2
0
6 4 20 2 46
Distance from the target mark on the switch X (mm)
Operating distance Y (mm)
ON range
OFF range
Sensing
surface
Target marks
Engineering Data
(ON to OFF)
Engineering
Data
(OFF to ON)
Minimum
operating distance
(OFF to ON)
Maximum
operating distance
(ON to OFF)
18
B
A
15 10 50 51015
Distance from the target mark on the switch Z (mm)
Operating distance Y (mm)
18
16
14
12
10
8
6
4
2
0
Z
Y
Sensing
surface
Target marks
ON range
OFF range
Engineering Data
(ON to OFF)
Engineering
Data
(OFF to ON)
Minimum
operating distance
(OFF to ON)
Maximum
operating distance
(ON to OFF)
B