Datasheet
D40A
10
Connections
Internal Circuit Diagram
D40A-1C@
D40A and G9SX-NS
@
Wiring
Example: Wiring a Single Switch
*1. The auxiliary output load current must be 10 mA max.
*2. When connecting a XS2F series connector with cable to a
connector type, the color of the auxiliary output cable is gray.
Example: Wiring Multiple Switches
Connect Up to 30 Non-contact Door Switches
Wiring of Inputs and Outputs
Note: When connecting a XS2F series connector with cable to a connector type, the color of the auxiliary output cable is gray.
Internal circuit
Brown
Blue
White
Black
Ye l l o w
White
G9SX-NS202-@
G9SX-NSA222-T03-@
Auxiliary output load *
1
D40A-1C@
D1 D2 D3 D4 A2
Black
Brown
Blue
Yellow
*
2
G9SX-NS202-@
G9SX-NSA222-T03-@
White
D1 D2 D3 D4
White
White
Black
Black
Black
Brown
Brown
Brown
Blue
Blue
Blue
Signal name Wire color
Pin No. of
connector type
Description of operation
Non-contact Door Switch
power supply input
+Brown 1
Supplies power to the D40A.
Connect to the D3 and D4 terminal of the G9SX-NS@.
-Blue 3
Non-contact Door Switch input White 2
Inputs signals from the G9SX-NS@.
The Non-contact Door Switch input must be ON as a required condition for
the Non-contact Door Switch output to be ON.
Non-contact Door Switch
output
Black 4
Turns ON and OFF according to actuator detection and the status of the
Non-contact Door Switch input.
Auxiliary output
(PNP open-collector output)
Yellow 5 Turns ON when actuator is detected.
For more information on connection terminal and wiring of G9SP, refer to G9SP Series Safety Controller
OPERATION MANUAL (Man. No. Z922).
4
12
3
5
Pin arrangement of connector type