Datasheet
375
Programmable
Controllers
C200H Group-2 High-density I/O Units
Note: C200H Units cannot be used with CS1D CPU Units.
Connectors for CS1 32- and 64-point I/O units, and C200H Group-2 High-density I/O Units
Note: 1. Refer to page 384 (Wiring Devices) for details. (Square boxes indicate the cable length.)
2. The XW2Z-@@@D, CS1W-OD@@@, and C200H-OD@@@ cannot be connected. Only the inputs of the CS1W-MD@@@ can be connect-
ed.
Connectors for CS1 96-point I/O Units
Note: Refer to page 384 (Wiring Devices) for details. (Square boxes indicate the cable length.)
Classifica-
tion
Name Specifications Mountable Racks Words
allocated
(CIO 0000 to
CIO 0319)
Model Standards
CPU
Rack
C200H
Expansion
I/O Racks
CS1
Expansion
Racks
CS1
Long-
distance
Racks
SYSMAC
BUS
Slave
Racks
C200H
Group-2
High-density
Input Units
(See note.)
DC Input Units 24 VDC, 32 inputs Yes Yes Yes No No 2 C200H-ID216 U, C, N, L, CE
24 VDC, 64 inputs Yes Yes Yes No No 4 C200H-ID217
24 VDC, 32 inputs, 6 mA Yes Yes Yes No No 2 C200H-ID218 U, C, CE
24 VDC, 64 inputs, 6 mA Yes Yes Yes No No 4 C200H-ID219
12 VDC, 64 inputs Yes Yes Yes No No 4 C200H-ID111 U, C
C200H
Group-2
High-density
Output Units
(See note.)
Transistor Out-
put Units
16 mA/4.5 V to
100 mA/26.4 V,
32 sinking outputs
Yes Yes Yes No No 2 C200H-OD218 U, C, N, L, CE
0.5 A/ 24 VDC,
32 sourcing outputs, load
short-circuit
protection
Yes Yes Yes No No 2 C200H-OD21B U, C, CE
16 mA/4.5 V to 100mA/
26.4 V,
64 sinking outputs
Yes Yes Yes No No 4 C200H-OD219 U, C, N, L, CE
Part Connection Remarks Model Standards
Applicable connector Soldered
(included with Unit)
From Fujitsu
Socket: FCN-361J040-AU
Connector bar: FCN-360C040-J2
C500-CE404
---
Crimped From Fujitsu
Socket: FCN-363J040
Connector bar: FCN-360C040-J2
Contacts: FCN-363J-AU
C500-CE405
Pressure welded From Fujitsu: FCN-367J040-AU C500-CE403
Terminal block
connection parts
1:1 connections Special Cable For CS1W-ID231/ID261/OD231/
OD232/OD261/OD262/MD261/
MD262 and C200H-ID216/ID217/
ID218/ID219/ID111/OD218/OD21B/
OD219
XW2Z-@@@B
(See note 1.)
Terminal Block Unit XW2B-40G4
XW2B-40G5
XW2D-40G6
1:2 connections Special Cable XW2Z-@@@D
(See notes 1 and 2.)
Terminal Block Unit XW2B-20G4
XW2B-20G5
XW2D-20G6
XW2C-20G5-IN16
Part Connection Remarks Model Standards
Applicable connectors Soldered
(included with Unit)
From Fujitsu
Socket: FCN-361J056-AU
Connector bar: FCN-360C056-J3
CS1W-CE561 ---
Crimped From Fujitsu
Socket: FCN-363J056
Connector bar: FCN-360C056-J3
Contacts: FCN-363J-AU
CS1W-CE562
Pressure welded From Fujitsu: FCN-367J056-AU CS1W-CE563
Terminal block 1:1 Special Cable For CS1W-ID291/OD291/OD292/
MD291/MD292
XW2Z-@@@H-1 (see note.)
Terminal Block Unit XW2B-60G4
XW2B-60G5
1:2 Special Cable XW2Z-@@@H-2 (see note.)
Terminal Block Unit XW2B-20G4
XW2B-20G5
XW2D-20G6
XW2B-40G4
XW2B-40G5
XW2D-40G6
1:3 Special Cable XW2Z-@@@H-3 (see note.)
Terminal Block Unit XW2B-20G4
XW2B-20G5
XW2D-20G6