Cat. No.
USB-Serial Conversion Cable CS1W-CIF31 User's Manual
Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property. DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
TABLE OF CONTENTS TABLE OF CONTENTS Notice: ......................................................................................................................... 2 OMRON Product References...................................................................................... 2 Visual Aids................................................................................................................... 2 TABLE OF CONTENTS...........................................................................
About this Manual About this Manual Thank you for purchasing the CS1W-CIF31 USB-Serial Conversion Cable. The CS1W-CIF31 USB-Serial Conversion Cable connects an OMRON PLC (or PT) to a personal computer's USB port. Please read this manual carefully and be sure you understand the information provided before attempting to install or operate the USB-Serial Conversion Cables. Be sure to read the precautions provided in the following section.
PRECAUTIONS PRECAUTIONS This section provides general precautions for using the USB-Serial Conversion Cable and related devices. The information contained in this section is important for the safe and reliable application of the USB-Serial Conversion Cable. You must read this section and understand the information contained before attempting to set up or operate a USB-Serial Conversion Cable and PLC system.
PRECAUTIONS █ Application Precautions Observe the following precautions when using the USB-Serial Conversion Cable. •These cables are designed specifically to connect a personal computer to an OMRON PLC or PT. Do not use them to connect any other devices and do not use a commercially available USB-serial conversion cable in place of these cables. Improper usage of these cables may result in damage to external devices, the PLC, or the PT. •Do not attempt to disassemble, repair, or modify any Units.
PRECAUTIONS █ EC Directives ● Applicable Directives •EMC Directives •Low Voltage Directive ● Concepts • EMC Directives OMRON devices that comply with EC Directives also conform to the related EMC standards so that they can be more easily built into other devices or the overall machine. The actual products have been checked for conformity to EMC standards (see the following note). Whether the products conform to the standards in the system used by the customer, however, must be checked by the customer.
Overview and Components Overview and Components Overview The CS1W-CIF31 USB-Serial Conversion Cable connects an OMRON PLC (Programmable Controller) or PT (Programmable Terminal) to a personal computer's USB port. The cable can be used once the required drivers (on the provided CD-ROM) have been installed in the personal computer.
Packing Lists Packing Lists D-sub Connector Cable (CS1W-CIF31) Name CS1W-CIF31 (USB Connector to D-sub Connector Conversion Cable) Drivers (On CD-ROM) User's Manual (this manual) (On CD-ROM in PDF format) Appearance Instruction Sheet 9
Specifications Specifications Compatible Operating Systems Windows 98/ME/2000/XP/Vista Compatible Software Applications The compatible software applications communicate with the PLC using the CX-Server or FinsGateway. The following software applications use CX-Server or FinsGateway. Name CX-Programmer CX-Simulator CX-Protocol CX-Position CX-Motion CX-Process NS-Designer PLC Reporter Communications software CX-Server (FinsGateway is used for network communications.
Specifications • Limitations when Using the NT Support Tool's System Installer 1) Windows 98 and Windows Me The system program cannot be downloaded to the PT through the USB-Serial Conversion Cable. 2) Windows 2000, Windows XP, and Windows Vista Only communications ports COM1 and COM2 can be used. Always change the communications port allocation for this device to COM1 or COM2 in the Microsoft Windows Device Manager (see note 1) and specify that port in the NT Support Tool's communications settings.
Specifications Connection Configurations The following table shows the connection configurations that can be used to connect an OMRON PLC (or PT) to a personal computer's USB port.
Specifications General Specifications USB Interface rating DTE speed Connector specifications Computer end PLC end Power supply Current consumption Operating Ambient temperature environment Ambient humidity Atmosphere Weight Conforms to USB Specification 1.1 115.
Dimensions Dimensions D-sub Connector Cable █ CS1W-CIF31 72.4 500 (46) (11.75) 14 (8) (4.5) 17.8 (12) 10 35.
System Configuration System Configuration CS/CJ-series PLCs ● Connecting to the Peripheral Port • Using a CS1W-CN226/626 Cable USB type A plug, male CS1W-CIF31 D-sub Connector CS/CJ-series PLC connection (9-pin male) Customizable Counter Unit connection CS/CJ-series peripheral connector D-sub Connector (9-pin female) Peripheral port Recommended cable: CS1W-CN226/626 • Using a CQM1-CIF02 Cable USB type A plug, male CS1W-CIF31 D-sub Connector (9-pin male) CS/CJ-series PLC connection (see note) D-sub Con
System Configuration • Using a XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V Cable for an RS-232C Connection USB type A plug, male CS1W-CIF31 D-sub Connector (9-pin male) D-sub Connector (9-pin female) CS/CJ-series PLC connection Customizable Counter Unit connection D-sub Connector (9-pin male) Peripheral port XW2Z-200S-CV/500S-CV or D-sub Connector XW2Z-200S-V/500S-V (See note.
System Configuration C-series PLCs █ C200HS, C200HX/HG/HE, C200H, C1000H, C2000H, CQM1, CPM1, CPM1A, CPM2A, or SRM1 • Connecting to the Peripheral Port Using a CQM1-CIF02 Cable USB type A plug, male CS1W-CIF31 D-sub Connector (9-pin male) D-sub Connector (9-pin female) C-series PLC connection C-series peripheral connector Peripheral port Recommended cable: CQM1-CIF02 • Connecting to the RS-232C Port Using a XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V Cable for an RS-232C Connection USB type A plug, m
System Configuration █ CQM1H and CPM2C PLCs • Connecting to the Peripheral Port Using a CS1W-CN226/626 Cable USB type A plug, male CS1W-CIF31 D-sub Connector (9-pin male) CQM1H PLC connection CPM2C PLC connection CS/CJ-series peripheral connector D-sub Connector (9-pin female) Peripheral port Recommended cable: CS1W-CN226/626 Using a CQM1-CIF02 Cable USB type A plug, male USB type A plug, male CS1W-CIF31 D-sub Connector (9-pin male) CQM1H PLC connection CPM2C PLC connection D-sub Connector (9-pin fema
System Configuration Using a XW2Z-200S-CV/500S-CV or XW2Z-200S-V/500S-V Cable for an RS-232C Connection USB type A plug, male CS1W-CIF31 D-sub Connector (9-pin male) CQM1H PLC connection CPM2C PLC connection D-sub Connector D-sub Connector (9-pin male) (9-pin female) Peripheral port XW2Z-200S-CV/500S-CV or CS/CJ-series peripheral connector D-sub Connector XW2Z-200S-V/500S-V (9-pin female) (See note.) CS1W-CN118 Note: With a CS/CJ-series PLC, the connection must be a host link connection.
System Configuration CVM1 and CV-series PLCs ● Connecting to the Peripheral Port • Using a CV500-CIF01 Cable USB type A plug, male CS1W-CIF31 D-sub Connector (9-pin male) D-sub 25-pin (female) to 9-pin (female) Adapter CVM1/CV-series PLC connection D-sub Connector CV-series peripheral connector (25-pin male) Peripheral port Recommended cable: CV500-CIF01 ● Connecting to the RS-232C Port • Using a XW2Z-200S-V/500S-V Cable USB type A plug, male CS1W-CIF31 D-sub Connector (9-pin male) CVM1/CV-series PLC
System Configuration PTs (NS and NT Series) ● Connecting to the RS-232C Port • Using a XW2Z-S002 Cable USB type A plug, male CS1W-CIF31 D-sub Connector (9-pin male) D-sub Connector D-sub Connector (9-pin male) (9-pin female) PT connection XW2Z-S002 RS-232C port Programmable Relay (ZEN) USB type A plug, male CS1W-CIF31 D-sub Connector (9-pin male) D-sub Connector (9-pin female) Personal Computer Connecting Cable ZEN-CIF01 Personal Computer Connector ZEN Personal Computer Connecting port 21
USB to PLC/PT Connection Tables USB to PLC/PT Connection Tables Connecting with the CS1W-CIF31 (D-sub Connector Cable) Computer CS1W-CIF31 Cable 2 (when necessary) Cable 1 PLC CS1W-N226/626 Programming Device Connecting Cable for a CS/CJ-series peripheral port CS1W-CN114 C-series peripheral port to CS/CJ-series peripheral port Conversion Cable OR CS1W-CIF31 USB Conversion Cable + CQM1H-CIF02 Programming Device Connecting Cable for a C-series peripheral port + CS1W-CN118 RS-232C to CS/CJ-series pe
USB to PLC/PT Connection Tables ● CS/CJ-series Serial Communications Board or Unit USB Cable 1 Conversion Cable Model Connector Model CS1W-CIF31 D-sub 9-pin, XW2Z-200S-CV female /500S-CV (Length: 2 or 5 m) D-sub 9-pin, XW2Z-200S-V female /500S-V (Length: 2 or 5 m) Cable 2 Connector RS-232C D-sub 9-pin, male RS-232C D-sub 9-pin, male Connector Model Not necessary Unit's port Connector RS-232C D-sub 9-pin, female Serial communications mode (Network type) Host link (SYSWAY) Not necessary ● Customizable
USB to PLC/PT Connection Tables ● CQM1H CPU Units USB Cable 1 Conversion Cable Model Connector Model CS1W-CIF31 D-sub 9-pin, CS1W-CN226/626 female (Length: 2 or 6 m) D-sub 9-pin, female D-sub 9-pin, female CQM1-CIF02 (Length: 3.
USB to PLC/PT Connection Tables ● C-series Host Link Unit (C200H-LK201-V1 or C120-LK201-V1) Note: The Host Link Unit cannot be used to connect a Programming Device (such as the CX-Programmer) to a C200HX/HG/HE with the "-ZE" suffix at the end of the model number.
USB to PLC/PT Connection Tables █ CVM1 and CV-series ● CVM1 and CV-series CPU Units USB Cable 1 Conversion Cable Model Connector Model CS1W-CIF31 D-sub 9-pin, D-sub 25-pin (female) female to D-sub 9-pin (female) adapter D-sub 9-pin, XW2Z-200S-V female /500S-V (Length: 2 or 5 m) Cable 2 Connector Connector Model D-sub 25-pin, D-sub 25-pin, CV500-CIF01 male female (Length: 6 m) D-sub 9-pin, male Unit's port Serial communications mode Connector (Network type) CV-series CV-series Peripheral bus peripheral p
Application Procedure Application Procedure This section explains how to connect a PLC CPU Unit to a personal computer with a USB-Serial Conversion Cable. Use the procedure below when connecting a PLC CPU Unit and personal computer. The Conversion Cable uses one of the computer's COM ports for communications.
Cable Connections Cable Connections Connecting the Cable Connect the computer and CPU Unit with one of the cable configurations shown in the USB to PLC/PT Connection Tables on page 22.
Installing the Drivers Installing the Drivers When the USB-Serial Conversion Cable is connected to the computer, the operating system (OS) will recognize the Cable as a new device. At this point, the driver can be installed with the wizard. The actual driver installation method depends on the OS being used. Windows 2000 is used in the examples in this section. Note The USB-Serial Conversion Cables are compatible with Windows XP.
Installing the Drivers 3. Select Search for a suitable driver for my device (recommended) and click the Next button. The following window will be displayed. Select Specify a location and click the Next button. The following window will be displayed. 4. Insert the CD-ROM containing the driver (the CD-ROM is in the same package as the Conversion Cable) into the computer's CD-ROM drive. Click the Browse button, select the ftdibus.inf file, from the following directory of the CD-ROM and click the OK button.
Installing the Drivers 6. The following window will be displayed if the driver was installed properly. Click the Finish button. 7. When the Finish button is clicked in step 6, the following window will be displayed for installation of the USB Serial Port driver. Follow the same procedure in steps 1 through 7 to install the USB Serial Port driver. (Driver installation is completed after installation of the USB Serial Port driver.) 8.
Installing the Drivers Verify that these two devices appear in the Device Manager.
Uninstalling the Drivers Uninstalling the Drivers Use the following procedure to delete (uninstall) the drivers for the USB-Serial Conversion Cable. 1. Disconnect the Conversion Cable from the computer. 2. Select Add/Remove Programs from the Control Panel. 3. Select OMRON USB-to-Serial Converter Drivers and click the Delete button. The following window will be displayed. 4. Click the Continue button.
Connecting Online from the CX-Programmer Connecting Online from the CX-Programmer The USB-Serial Conversion Cable uses one of the computer's COM ports to communicate. The communications port (COM port) allocated to the Conversion Cable must be selected with the CX-Programmer in order to connect online to a PLC or PT. Note: It may take some time for the computer to detect the cable after the cable is connected. This is not a malfunction.
Connecting Online from the CX-Programmer 4. Locate the Port Name setting and select the COM port being used by the Conversion Cable. Note If you fail to connect with this USB Cable, turn OFF auto baud rate detection if it is being used by your software. With the CX-Programmer, auto baud rate detection can be turned OFF by clearing the selection for it on the Network Settings dialog box.
Connecting Online from the CX-Programmer █ Changing the Allocated Communications Port The communications port (COM port) being used by the Conversion Cable can be changed with the following procedure. The actual change procedure depends on the operating system. This example shows the procedure for Windows 2000. Note If the new COM port is being used by another driver, that driver must be uninstalled. 1. Double-click OMRON CS1W-CIF3* USB Serial Port (COM@) in the Device Manager window. 2.
Connecting Online from the CX-Programmer 3. Click the Advanced button. The following window will be displayed. 4. Select the new COM port number from the COM Port Number list. 5. Click the OK button to change the COM port used by the Conversion Cable.
Using More than One Conversion Cable Using More than One Conversion Cable The operating system recognizes USB-Serial Conversion Cables individually. If a second Conversion Cable is connected after the driver has been installed, driver installation will be requested again. Install the driver from the CD-ROM again. If you do not own the CD-ROM and will use more than one Conversion Cable, copy the win2000_XP folder from the CD-ROM to a folder on your hard disk, and select this folder.
Revision History Revision History A manual revision code appears as a suffix to the catalog number on the front cover of the manual. Cat. No. W417-E1-03 Revision code The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version. Revision code Date Revised content 01 February 2003 Original production 02 October 2006 Page 7: Changed EMI standard number of EC Directives. Page 30: Changed the reference directory for the driver file.
Index Index C communications port changing ............................................................................................................. 36 verifying .............................................................................................................. 35 component names ..........................................................................................................
OMRON Corporation Control Devices Division H.Q. Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7109/Fax: (81)75-344-7149 Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No.
Authorized Distributor: Cat. No.