Datasheet

25
CJ2M-CPU3@/-CPU1@/-MD21@
Pulse I/O Module MIL connector Wiring Methods
To connect to a Terminal Block, use an OMRON Cable preassembled with the special connector or attach the special connector (sold separately)
to a cable yourself.
Using User-made Cables with Connector
Connector Models
Compatible Connector Specifications
MIL Flat Cable Connectors (40-pin Pressure-fitted Connectors)
MIL Loose Wire Crimp Connectors (40-pin Pressure-fitted Connectors)
Note: 1. Contacts are included with the Socket.
2. Select either the Hood Cover or the Partial Cover.
Wiring
We recommend using a cable with wires sized between 28 and 24 AWG (0.2 to 0.08 mm
2
). Use a wire with an outer diameter of 1.61 mm max.
Compatible Terminal Blocks
Name OMRON model number
Socket XG4M-4030
Stain Relief XG4M-4004
Set model number XG4M-4030-T
Recommended Flat Cable XY3A-200@
Name OMRON model number
Socket
AWG24 XG5M-4032-N
AWG26 to AWG28 XG5M-4035-N
Spare Contacts
(See note 1.)
AWG24 XG5W-0031-N
AWG26 to AWG28 XG5W-0034-N
Hood Cover (See note 2.) XG5S-4022
Partial Cover (See note 2.)
(2 required for each socket)
XG5S-2001
Recommended Cable Compatible Terminal Block Wiring method
Number of
terminals
Temperature (°C)
XW2Z-@@@K
XW2R-J40G-T Phillips screw
40 0 to 55XW2R-E40G-T Slotted screw (rise up)
XW2R-P40G-T Push-in spring
Socket
Stain relief
Hood Cover
Partial Cover
Socket