Datasheet
180 Programmable Controllers
Connecting to the Peripheral Port
Peripheral Port Connecting Cables
The following cables can be used for an RS-232C connection from the
computer to the peripheral port.
Connecting to the RS-232C Port
RS-232C Port Connecting Cables
Note: Cables with model numbers ending in “CV” are anti-static.
The following cables can be used for an RS-232C connection from the
computer to an RS-232C port. (Unlike “CV” models, however, they do
not support Peripheral Bus and do not use anti-static connectors.)
The following serial communications modes can be used to connect a
computer with the CX-Programmer to a CJ-series PLC.
Using a USB-Serial Conversion Cable to Connect to a Peripheral or RS-232C Port
General Specifications of USB-Serial Conversion Cable
OS with Drivers for USB-Serial Conversion Cable
Windows 98, ME, 2000, or XP
Applicable Software
CX-One is the integrated software for programming and configuration
of all Omron control system components, including PLCs, HMI, drives,
temperature controllers and advanced sensors.
It includes the functionality of previously released individual software
tools like CX-Programmer, CX-Designer, CX-Simulator, CX-Protocol,
and network configuration tools.
Peripheral Port Connecting Cables
RS-232C Port Connecting Cables
Connection in Tool Bus Mode is not possible. The connector does not have ESD measures.
Cable Length Computer con-
nector
CS1W-CN226 2.0 m D-sub, 9-pin, male
CS1W-CN626 6.0 m
Mode Connecting cables Length Computer
connector
Peripheral
bus or
Host Link
XW2Z-200S-CV or
XW2Z-500S-CV
CS1W-
CN118
2 or 5 m +
0.1 m
D-sub, 9-pin,
male
Host Link XW2Z-200S-V or XW2Z-
500S-V
Peripheral port
Connecting Cable
RS-232C,
9-pin (D-sub)
RS-232C cable
Peripheral port
CS1W-CN118
Mode Cable Length Computer connector
Peripheral Bus or
Host Link
XW2Z-200S-CV 2.0 m D-sub, 9-pin
XW2Z-500S-CV 5.0 m
Mode Cable Length Computer connector
Host Link XW2Z-200S-V 2.0 m D-sub, 9-pin
XW2Z-500S-V 5.0 m
Mode Features
Peripheral Bus The faster mode, peripheral bus is generally used for CX-Pro-
grammer connections.
Only 1:1 connections are possible. The baud rate is automatical-
ly detected with the CJ1.
Host Link A standard protocol for host computers.
Slower than peripheral bus, but allows modem or optical adapter
connections, or long-distance or 1:N connections via RS-422A/
485.
RS-232C,
9-pin (D-sub)
RS-232C port on CPU Unit
RS-232C cable
XW2Z-200S-CV (2 m)
XW2Z-500S-CV
(
5 m
)
USB interface standard Conforms to USB Specification 1.1.
DTE speed 115.2 Kbits/s
Connectors On computer USB (A plug connector, male)
On PLC RS-232C (D-sub, 9-pin, female)
Power supply Bus power (supplied from upstream, 5 V
DC)
IBM PC/AT or compatible
with USB port
Peripheral or RS-232C port
CS1W-CIF31
USB-Serial Conversion Cable
Serial Connecting Cable:
CS1W-CN226/CN626
XW2Z-200S-CV/500S-CV
XW2Z-200S-V/500S-V
CQM1-CIF02
Current consumption 35 mA
Operating
environment
Ambient temperature 0 to 55 °C
Ambient humidity 10% to 90% (with no condensation)
Ambient atmosphere No corrosive gases
Weight 50 g
Computer Serial Communications Node Connecting Cable model number Length Computer connector
IBM PC/AT
or compatible
Tool bus or SYSMAC WAY CS1W-CIF31 CS1W-CN226 0.5 m + 2.0 m USB (A plug connector)
CS1W-CN626 0.5 m + 6.0 m
CS1W-CIF31 XW2Z-200S-CV/
XW2Z-500S-CV
CS1W-CN118 0.5 m + (2.0 m or 5.0 m) + 0.1 m
SYSMAC WAY CS1W-CIF31 XW2Z-200S-V/
XW2Z-500S-V
0.5 m + (2.0 m or 5.0 m) + 0.1 m
Computer Serial Communications Node Connecting Cable model number Length Computer connector
IBM PC/AT
or compatible
Tool bus or SYSMAC WAY CS1W-CIF31 XW2Z-200S-CV 0.5 m + 2.0 m USB (A plug connector)
XW2Z-500S-CV 0.5 m + 5.0 m
SYSMAC WAY CS1W-CIF31 XW2Z-200S-V (See note.) 0.5 m + 2.0 m
XW2Z-500S-V (See note.) 0.5 m + 5.0 m
Y201-EN2-03.book Seite 180 Donnerstag, 30. März 2006 1:52 13