Datasheet

11
CJ1M-CPU2@
Functions Supported for Unit Version 2.0 or Later
CX-Programmer 4.0 or higher must be used to enable using the functions added for unit version 2.0.
CJ1-H/CJ1M CPU Units
User programs that contain functions supported only by CPU Units with unit version 2.0 or later cannot be used on CS/CJ-series Pre-Ver. 2.0 CPU
Units. An error message will be displayed if an attempt is made to download programs containing unit version s.0 functions to a Pre-Ver. 2.0 CPU
Unit, and the download will not be possible.
If an object program file (.OBJ) using these functions is transferred to a Pre- Ver. 2.0 CPU Unit, a program error will occur when operation is started
or when the unit version 2.0 function is executed, and CPU Unit operation will stop.
Function
CJ1M CPU Units
CJ1M-CPU12/13/22/23 CJ1M-CPU11/21
Unit version
2.0 or later
Other unit
versions
Unit version
2.0 or later
Downloading and Uploading Individual Tasks OK OK
Improved Read Protection Using Passwords OK OK
Write Protection from FINS Commands Sent to
CPU Units via Networks
OK OK
Online Network Connections without I/O
Tables
OK
(Supported
if I/O tables are automatically
generated at startup.)
OK
Communications through a Maximum of 8
Network Levels
OK OK
Connecting Online to PLCs via NS-series PTs OK
OK from
lot number 030201
OK
Setting First Slot Words
OK for up to
64 groups
OK for up to
8 groups
OK for up to
64 groups
Automatic Transfers at Power ON without a
Parameter File
OK OK
Automatic Detection of I/O Allocation Method
for Automatic Transfer at Power ON
OK OK
Operation Start/End Times OK OK
New Application
Instructions
MILH, MILR, MILC OK OK
=DT, <>DT, <DT, <=DT,
>DT, >=DT
OK OK
BCMP2OKOKOK
GRY OK
OK from
lot number 030201
OK
TPO OK OK
DSW, TKY, HKY, MTR,
7SEG
OK OK
EXPLT, EGATR, ESATR,
ECHRD, ECHWR
OK OK
Reading/Writing CPU Bus
Units with IORD/IOWR
OK OK
PRV2
OK, but only for CPU Units with built-
in I/O
OK, but only for CPU Units with built-
in I/O