Datasheet
2 Frequency inverters
Type designation
200 V class
400 V class
Specifications
Single-phase: 3G3MX2-@ B001 B002 B004 B007
1
1. Three phase model use forced-air-cooling but single phase model is self cooling.
B015 B022 - - - - -
Three-phase: 3G3MX2-@ 2001 2002 2004 2007 2015 2022 2037 2055 2075 2110 2150
Motor
kW
2
2. Based on a standard 3-Phase standard motor.
For VT setting 0.2 0.4 0.55 1.1 2.2 3.0 5.5 7.5 11 15 18.5
For CT setting 0.1 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15
Output
characteristics
Inverter capacity kVA
200 VT
0.4 0.6 1.2 2.0 3.3 4.1 6.7 10.3 13.8 19.3 23.9
200 CT
0.2 0.5 1.0 1.7 2.7 3.8 6.0 8.6 11.4 16.2 20.7
240 VT
0.4 0.7 1.4 2.4 3.9 4.9 8.1 12.4 16.6 23.2 28.6
240 CT
0.3 0.6 1.2 2.0 3.3 4.5 7.2 10.3 13.7 19.5 24.9
Rated output current (A) at VT 1.2 1.9 3.5 6.0 9.6 12.0 19.6 30.0 40.0 56.0 69.0
Rated output current (A) at CT 1.0 1.6 3.0 5.0 8.0 11.0 17.5 25.0 33.0 47.0 60.0
Max. output voltage Proportional to input voltage: 0..240 V
Max. output frequency 400 Hz
Power
supply
Rated input voltage
and frequency
Single-phase 200..240 V 50/60 Hz
3-phase 200..240 V 50/60 Hz
Allowable voltage fluctuation -15%..+10%
Allowable frequency fluctuation 5%
Braking torque
At short-time
deceleration
At capacitor
feedback
100%: <50Hz
50%: <60Hz
70%:
<50Hz
50%:
<60Hz
Approx 20% -
Cooling method
Self cooling
3
3. Forced air cooling for IP54 models.
Forced-air-cooling
Three-phase: 3G3MX2-@ 4004 4007 4015 4022 4030 4040 4055 4075 4110 4150
Motor
kW
1
1. Based on a standard 3-Phase standard motor.
For VT setting 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5
For CT setting 0.4 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15
Output
characteristics
Inverter capacity kVA
380 VT
1.3 2.6 3.5 4.5 5.7 7.3 11.5 15.1 20.4 25.0
380 CT
1.1 2.2 3.1 3.6 4.7 6.0 9.7 11.8 15.7 20.4
480 VT
1.7 3.4 4.4 5.7 7.3 9.2 14.5 19.1 25.7 31.5
480 CT
1.4 2.8 3.9 4.5 5.9 7.6 12.3 14.9 19.9 25.7
Rated output current (A) at VT 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23.0 31.0 38.0
Rated output current (A) at CT 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18.0 24.0 31.0
Max. output voltage Proportional to input voltage: 0..480 V
Max. output frequency 400 Hz
Power
supply
Rated input voltage
and frequency
3-phase 380..480 V 50/60 Hz
Allowable voltage
fluctuation
-15%..+10%
Allowable frequency
fluctuation
5%
Braking torque
At short-time
deceleration
At capacitor
feedback
100%: <50Hz
50%: <60Hz
70%:
<50Hz
50%:
<60Hz
-
Cooling method
Self cooling
2
2. Forced air cooling for IP54 models.
Forced-air-cooling
MX2 series
3G3MX2-AB002-@ -E@
A: IP20
D: IP54 (Includes Class 2 EMC lter)
Voltage:
B: Single-phase 200 VAC
2: Three-phase 200 VAC
4: Three-phase 400 VAC
Max. applicable motor output
002: 0,2 kW
~
150: 15,0 kW
P: Finless
C: IP54 ready for customization
E: Europe standard