Datasheet

16 Frequency inverters
D Braking unit, braking resistor unit
E Computer software
Inverter Braking resistor unit
Voltage
Max.
motor
kW
Inverter 3G3MX2@
Connectable
min.
resistance
Inverter mounted type
(3 %ED, 10 sec max)
Braking
torque %
Inverter mounted type
(10%ED, 10 sec max)
Braking
torque %
1-phase 3-phase Type AX- Resist Type AX- Resist
200 V
(Single-/
Three-
phase)
0.12 B001 2001
100
REM00K1400-IE 400
200
REM00K1400-IE 400
200
0.25 B002 2002 180 180
0.55 B004 2004
REM00K1200-IE 200
180 REM00K1200-IE 200 180
1.1 B007 2007
50
100 REM00K2070-IE 70 200
1.5 B015 2015
REM00K2070-IE 70
140 REM00K4075-IE 75 130
2.2 B022 2022
35
90 REM00K4035-IE 35 180
4.0 2040 REM00K4075-IE 75 50 REM00K6035-IE 35 100
5.5 2055 20
REM00K4035-IE 35
75 REM00K9020-IE 20 150
7.5 2075
17
55 REM01K9017-IE 17 110
11 2110 REM00K6035-IE 35 40 REM02K1017-IE 17 75
15 2150 10 REM00K9017-IE 17 55 REM03K5010-IE 10 95
400 V
(Three-
phase)
0.55 4004
180
REM00K1400-IE 400
200
REM00K1400-IE 400
200
1.1 4007 200 200
1.5 4015 REM00K1200-IE 200 190 REM00K2200-IE 200 190
2.2 4022
100
REM00K2200-IE 200 130
REM00K5120-IE 120
200
3.0 4030
REM00K2120-IE 120
160 160
4.0 4040 120 REM00K6100-IE 100 140
5.5 4055
70
REM00K4075-IE 75
140 REM00K9070-IE 70 150
7.5 4075 100 REM01K9070-IE 70 110
11 4110 REM00K6100-IE 100 50 REM02K1070-IE 70 75
15 4150 35 REM00K9070-IE 70 55 REM03K5035-IE 35 110
Types Model Description Installation
Software
CX-Drive Computer software Configuration and monitoring software tool
CX-One Computer software Configuration and monitoring software tool
€Saver
Computer software Software tool for Energy Saving calculation
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. I113E-EN-05