MX2 15
A Chokes A Output AC reactor
B Accessories
C Communication option boards
Model Diameter Description
AX-FER2102-RE 21 For 2.2 KW motors or below
AX-FER2515-RE 25 For 15 KW motors or below
AX-FER5045-RE 50 For 45 KW motors or below
Inverter
AC Reactor
Voltage Model 3G3MX2-@ Reference
200 VAC
AB001 / AB002 / AB004
A2001 / A2002 / A2004
AX-RAO11500026-DE
AB007 / A2007 AX-RAO07600042-DE
AB015 / A2015 AX-RAO04100075-DE
AB022 / A2022 AX-RAO03000105-DE
A2037 AX-RAO01830160-DE
A2055 AX-RAO01150220-DE
A2075 AX-RAO00950320-DE
A2110 AX-RAO00630430-DE
A2150 AX-RAO00490640-DE
400 VAC
A4004 / A4007 / A4015 AX-RAO16300038-DE
A4022 AX-RAO11800053-DE
A4030 / A4040 AX-RAO07300080-DE
A4055 AX-RAO04600110-DE
A4075 AX-RAO03600160-DE
A4110 AX-RAO02500220-DE
A4150 AX-RAO02000320-DE
Types Model Description Functions
Digital
operator
AX-OP05-E LCD remote operator 5 Line LCD remote operator with copy function, cable length max. 3m.
3G3AX-CAJOP300-EE Remote operator cable 3 meters cable for connecting remote operator
3G3AX-OP01 LED remote operator LED remote operator, cable length max. 3m
4X-KITMINI Mounting kit for LED operator Mounting kit for LED operator on panel
3G3AX-OP05-H-E Operator holder Holder to put the AX-OP05-E inside of the cabinet
Accessories
AX-CUSBM002-E PC configuration cable Mini USB to USB connector cable
Types Model Description Functions
Communication options
3G3AX-MX2-PRT Profibus option card
Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through communications with the host con-
troller.
3G3AX-MX2-DRT DeviceNet option card
3G3AX-MX2-ECT EtherCAT option card
3G3AX-MX2-CRT CompoNet option card
3G3AX-MX2-MRT MECHATROLINK-II option card
3G3AX-MX2-EIP EtherNet/IP option card
I/O option
3G3AX-MX2-EIO15-E Extra input/output option board
1 analog voltage input, 1 analog current input, 1 analog voltage output, 8 discrete logic inputs,
4 discrete logic outputs