Datasheet

A22NE-P
27
A22NE-PD A22NE-P A22E Common Note
Common Accessories and Tools
Characteristics
*1.
State when an LED is not added between terminals of the same polarity on a lighting unit. Does not apply to lighted-type 100 to 200 V lighting units.
*2. With no icing or condensation.
*3. The degree of protection from the front of the panel.
*4. The degree of protection is IP65 even with an integrated control box, but the system is not oil resistant.
Operating Characteristics
* Rotation torque value.
Terminal Arrangement (BOTTOM VIEW)
Operation Turn-reset Pull-reset
Non-lighted model Lighted Model Non-lighted model
Item A22NE-@-P@@@-N A22NE-M-P@@@-@ A22NE-MP-P@@@-N
A22NE-MP-P
@@@
-N-69K
Allowable operating
frequency
Mechanical
30 operations/minute or less (One operation consists of set and reset operations.)
Electrical 30 operations/minute or less (One operation consists of set and reset operations.)
Insulation resistance
*
1
100 M min. (at 500 VDC)
Contact resistance 100 m max. (initial value)
Dielectric
strength
Between
terminals of
same polarity*1
2,500 VAC, 50/60 Hz 1 minute (initial value)
Between each
terminal and
ground
2,500 VAC, 50/60 Hz 1 minute (initial value)
Vibration
resistance
Malfunction
10 to 55 Hz, 1.5 mm double amplitude (contact separation within 1 ms)
Shock
resistance
Malfunction
250 m/s
2
max. (contact separation within 1 ms)
Durability
Mechanical
300,000 operations min. (One operation consists of set and reset operations.)
100,000 operations min.
(One operation consists of
set and reset operations.)
Electrical 300,000 operations min. (One operation consists of set and reset operations.)
100,000 operations min.
(One operation consists of
set and reset operations.)
Ambient operating temperature
*
2
-20 to +70°C -20 to +55°C -20 to +70°C
Ambient operating humidity 35 to 85% RH
Ambient storage temperature
*
2
-40 to +70°C
Degree of protection*3
IP65 oil-resistant models
*
4
IP65
IP65 oil-resistant models
*
4
IP69K
Electric shock protection class
Class II
PTI (tracking characteristic) 175
Degree of contamination 3 (EN 60947-5-1)
Minimum direct opening stroke 11 mm
Minimum direct opening force
45 N
Conditional short-circuit current
100 A (EN 60947-5-1)
Wight (for a 40-dia. head
1NC/1NO Operation Unit)
Approx. 55g Approx. 60g Approx. 85 g Approx. 115 g
Item
Turn-reset Pull-reset
Lighted / non-lighted models Non-lighted model
Non-lighted model (Models with IP69K)
Total travel force (TTF) 45 N max. 60 N max. 70 N max.
Return force (RF) 0.25N·m * max. 60 N max. 70 N max.
Total travel (TT) 10 ±1 mm 5.5 ±1 mm 5.5 ±1 mm
Non-lighted (two contacts) Non-lighted (three contacts) Lighted (two contacts)
Terminal
(insertion) hole
Lock lever
(17.6°)
(20°)
10
20
31.9
4
Switch Blocks
Lock lever
Terminal
(insertion) hole
(17.6°)
(20°)
10
20
31.9
4
Switch Blocks
Lock lever
Lighting unit
Terminal
(insertion) hole
(17.6°)
(20°)
10
20
31.9
4
Switch Blocks