Datasheet
A22E
48
A22NE-PD A22NE-P A22E Common Note
Common Accessories and Tools 
Installation
Mounting to the Panel
Assembling the Cap
(1) Preparing the Panel (2) Mounting the Operation Unit on the Panel
• The panel dimensions are shown below.
• The panel thickness must be 1 to 5 mm. 
• Always use a 25-mm-dia. A22Z-R25 Lock Ring for a 25-mm-dia. hole. 
IP65 degree of protection will be lost if the 25-mm-dia. Lock Ring is not used 
because of the larger size of a 25-mm-dia. hole. 
• When painting or coating the panel, make sure that the specified panel 
dimensions apply to the panel after painting or coating.
• Insert the Operation Unit from the front surface of the panel, insert the Lock 
Ring and the Tightening Nut from the terminal side, then tighten the Ring. 
Before tightening, check that the rubber washer is present between the 
Operation Unit and the panel.
• Align the Lock Ring with the groove in the casing, then insert the Lock Ring so 
that its edge is located on the panel side.
• Tighten the Tightening Nut at a torque of 1.0 to 2.0 N·m.
• When using a Lock Ring, replace with the supplied Lock Ring, insert the 
projecting part into the lock slot, and then tighten the Tightening Nut.
(3) Mounting the Switch on the Operation Unit
• Insert the Operation Unit into the Switch Unit, aligning the arrow mark inscribed 
on the Case with the lever on the Switch Blocks, then move the lever in the 
direction indicated by the arrow in the following figure.
(4) Removing the Switch
Emergency Stop Switch
• Insert the protrusion of the Tightening Wrench (A22Z-3905) into the Cap slot and then turn to remove the Cap.
22.3 dia.
+0.4
 0
25 dia.
+0.5
 0
22.3 dia.
+0.4
 0
24.1
+0.4
 0
3.2
R0.8 max.
With Lock Ring Without Lock Ring
+0.2
 0
Hold here
Tightening Nut
Lock Ring
Rubber Washer
Panel
Panel
Lock Ring
Projecting 
part
1. When the panel cutout dimension is 
25 dia., remove the supplied rubber 
washer and mount the 25-dia. Ring as 
shown below. (Since the A22Z-R25 is 
not attached to the main body, order 
separately.) When using a Legend 
Plate (Order Separately), do not 
remove the rubber washer.
22 dia.
22.3 dia.
25 dia.
25 dia.
22.3 dia.
0.5 1.3
Panel
Lock Ring
Tightening Nut
25-dia. Ring
(A22Z-R25)
Operation Unit
Rubber washer 
(mounted to 
Operation Unit) 
When not using a 
Legend Plate, 
remove the rubber 
washer. 
(If required)
Legend Plates for 
Emergency Stop 
(order separately)
2. When the panel cutout 
dimension is 30 dia., use resin 
attachment A22Z-A30. Since it 
is not attached to the main 
body, order separately.
Operation Unit
Rubber washer
(mounted to 
Operation Unit)
30-dia. 
Resin Attachment
(A22Z-A30)
Rubber washer
(included)
Mounting
panel
Lock Ring
Tightening Nut
Lever
Arrow mark
Operation 
Unit
• Move the lever in the direction indicated by the arrow in the following figure, 
then pull the Operation Unit or the Switch Blocks.
Since the lever has a hole with an inside diameter of 6.5 mm, the lever can 
be moved in the specified direction by inserting a screwdriver into the hole 
and then moving the screwdriver.
Screwdriver
Cap slot
Protrusion