Datasheet

6 DC Power Relays (60-A, 100-A Models) G9EA-1
Specifications
Ratings
Coil
Note: 1. The figures for the rated current and coil resistance are for a coil temperature of 23°C and have a tolerance of ±10%.
2. The figures for the operating characteristics are for a coil temperature of 23
°C.
3. The figure for the maximum voltage is the maximum voltage that can be applied to the relay coil.
Contacts
Characteristics
Note: 1. The above values are initial values at an ambient temperature of 23°C unless otherwise specified.
2. The contact resistance was measured with 1 A at 5 VDC using the voltage drop method.
3. The insulation resistance was measured with a 500-VDC megohmmeter.
4. The impulse withstand voltage was measured with a JEC-212 (1981) standard impulse voltage waveform (1.2
× 50 µs).
5. The mechanical endurance was measured at a switching frequency of 3,600 operations/hr.
6. The electrical endurance was measured at a switching frequency of 60 operations/hr.
Rated voltage Rated current Coil resistance Must-operate
voltage
Must-release
voltage
Maximum voltage
(See note 3.)
Power
consumption
12 VDC 417 mA 28.8
75% max. of rated
voltage
8% min. of rated
voltage
130% of rated volt-
age (at 23°C within
10 minutes)
Approx. 5 W
24 VDC 208 mA 115.2
48 VDC 102 mA 469.3
60 VDC 86.2 mA 695.7 Approx. 5.2 W
100 VDC 53.6 mA 1,864
Approx. 5.4 W
Item Resistive load
G9EA-1(-B) G9EA-1(-B)-CA
Rated load 60 A at 400 VDC, 100 A at 120 VDC 30 A at 400 VDC
Rated carry current 60 A 100 A
Maximum switching voltage 400 V 400 V
Maximum switching current 100 A 30 A
Item G9EA-1(-B) G9EA-1(-B)-CA
Contact resistance (See note 2.)
30 m max. (0.6 m typical) 10 m max. (0.3 m typical)
Contact voltage drop 0.1 V max.
(for a carry current of 60 A)
0.1 V max.
(for a carry current of 100 A)
Operate time
50 ms max.
Release time
30 ms max.
Insulation resistance
(See note 3.)
Between coil and contacts
1,000 M min.
Between contacts of the same polarity
1,000 M min.
Dielectric strength Between coil and contacts
2,500 VAC, 1 min
Between contacts of the same polarity
2,500 VAC, 1 min
Impulse withstand voltage (See note 4.)
4,500 V
Vibration resistance Destruction
10 to 55 to 10 Hz, 0.75-mm single amplitude (Acceleration: 2.94 to 88.9 m/s
2
)
Malfunction
10 to 55 to 10 Hz, 0.75-mm single amplitude (Acceleration: 2.94 to 88.9 m/s
2
)
Shock resistance Destruction
490 m/s
2
Malfunction
196 m/s
2
Mechanical endurance (See note 5.)
200,000 ops. min.
Electrical endurance (See note 6.)
120 VDC, 100 A, 3,000 ops. min. 400 VDC, 30 A, 1,000 ops. min.
400 VDC, 60 A, 3,000 ops. min. 120 VDC, 30 A, 2,500 ops. min.
400 VDC, 30 A, 30,000 ops. min. ---
Short-time carry current 100 A (10 min) 150 A (10 min)
Maximum interruption current 600 A at 300 VDC (5 times) ---
Overload interruption 180 A at 400 VDC (100 times min.) 100 A at 120 VDC (150 times min.)
Reverse polarity interruption
60 A at 200 VDC (1,000 times min.) ---
Ambient operating temperature
40 to 70°C (with no icing or condensation)
Ambient operating humidity 5% to 85%
Weight Approx. 310 g