Datasheet

12 DC Power Relays (200-A Models) G9EC-1
Specifications
Ratings
Coil
Note: 1. The figures for the rated current and coil resistance are for a coil temperature of 23°C and have a tolerance of ±10%.
2. The figures for the operating characteristics are for a coil temperature of 23
°C.
3. The figure for the maximum voltage is the maximum voltage that can be applied to the relay coil.
Contacts
Characteristics
Note: 1. The above values are initial values at an ambient temperature of 23°C unless otherwise specified.
2. The contact resistance was measured with 1 A at 5 VDC using the voltage drop method.
3. The insulation resistance was measured with a 500-VDC megohmmeter.
4. The impulse withstand voltage was measured with a JEC-212 (1981) standard impulse voltage waveform (1.2
× 50 µs).
5. The mechanical endurance was measured at a switching frequency of 3,600 operations/hr.
6. The electrical endurance was measured at a switching frequency of 60 operations/hr.
Rated voltage Rated current Coil resistance Must-operate
voltage
Must-release
voltage
Maximum voltage
(See note 3.)
Power
consumption
12 VDC 938 mA 12.8
75% max. of rated
voltage
8% min. of rated
voltage
110% of rated volt-
age (at 23°C within
10 minutes)
Approx. 11 W
24 VDC 469 mA 51.2
48 VDC 234 mA 204.8
60 VDC 188 mA 320.0
100 VDC 113 mA 888.9
Item Resistive load
G9EC-1(-B)
Rated load 200 A at 400 VDC
Rated carry current 200 A
Maximum switching voltage 400 V
Maximum switching current 200 A
Item G9EC-1(-B)
Contact resistance (See note 2.)
30 m max. (0.2 m typical)
Contact voltage drop 0.1 V max. (for a carry current of 200 A)
Operate time
50 ms max.
Release time
30 ms max.
Insulation resistance
(See note 3.)
Between coil and contacts
1,000 M min.
Between contacts of the same polarity
1,000 M min.
Dielectric strength Between coil and contacts
2,500 VAC, 1 min
Between contacts of the same polarity
2,500 VAC, 1 min
Impulse withstand voltage (See note 4.)
4,500 V
Vibration resistance Destruction
10 to 55 to 10 Hz 0.75-mm single amplitude (Acceleration: 2.94 to 88.9 m/s
2
)
Malfunction
10 to 55 to 10 Hz 0.75-mm single amplitude (Acceleration: 2.94 to 88.9 m/s
2
)
Shock resistance Destruction
490 m/s
2
Malfunction
196 m/s
2
Mechanical endurance (See note 5.)
200,000 operations min.
Electrical endurance (resistive load) (See note 6.)
400 VDC, 200 A, 3,000 operations min.
Short-time carry current 300 A (15 min)
Maximum interruption current 1,000 A at 400 VDC (10 times)
Overload interruption 700 A at 400 VDC (40 times min.)
Reverse polarity interruption
200 A at 200 VDC (1,000 times min.)
Ambient operating temperature
40 to 50°C (with no icing or condensation)
Ambient operating humidity 5% to 85%
Weight Approx. 560 g