Datasheet

233
Text
232
Text Surface-Mounting Signal Relay – G6S
Contact Ratings
Load Resistive load (cosφ = 1)
Rated Load 0.5 A at 125 VAC; 2 A at 30 VDC
Contact material Ag (Au-alloy)
Rated Carry Current 2 A
Max. switching voltage 250 VAC, 220 VDC
Max. switching current 2 A
Max. switching power 62.5 VA, 60 W
Failure rate (reference value) 10 µA at 10 mVDC
(see note)
Note: P level: λ
60
= 0.1 x 10
-6
/operation. This value was measured at a switching frequency of 120 operations/min and the criterion of
contact resistance is 50Ω. This value may vary depending on the operating environment. Always double-check relay suitability under
actual operating conditions.
Single-side Stable EN60950 Approved Type (G6S-2-Y, G6S-2F-Y, G6S-2G-Y)
Rated voltage 5 VDC 12 VDC 24 VDC
Rated current 40 mA 16.7 mA 9.6 mA
Coil resistance 125 Ω 720 Ω 2,504 Ω
Must operate voltage 75% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 170% of rated voltage at 23°C 170% of rated voltage at 23°C
Power consumption Approx. 200 mW Approx. 230 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
Signal Relays
Surface-Mounting Signal Relay – G6S
Specifications
Coil Ratings
Single-side Stable Type (G6S-2, G6S-2F, G6S-2G)
Rated voltage 4.5 VDC 5 VDC 12 VDC 24 VDC
Rated current 31.0 mA 28.1 mA 11.7 mA 8.3 mA
Coil resistance 145 Ω 178 Ω 1,028 Ω 2,880 Ω
Must operate voltage 75% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 200% of rated voltage at 23°C 170% of rated
voltage at 23°C
Power consumption Approx. 140 mW Approx. 200 mW
Single-winding Latching Type (G6SU-2, G6SU-2F, G6SU-2G)
Rated voltage 4.5 VDC 5 VDC 12 VDC 24 VDC
Rated current 22.2 mA 20 mA 8.3 mA 6.3 mA
Coil resistance 203 Ω 250 Ω 1,440 Ω 3,840 Ω
Coil inductance Armature OFF
0.27 0.36 2.12 5.80
(H) (ref. value) Armature ON
0.14 0.18 1.14 3.79
Must set voltage 75% max. of rated voltage
Must reset voltage 75% min. of rated voltage
Max. voltage 180% of rated voltage at 23°C
Power consumption Approx. 100 mW Approx. 150 mW
Double-winding Latching Type (G6SK-2, G6SK-2F, G6SK-2G)
Rated voltage 4.5 VDC 5 VDC 12 VDC 24 VDC
Rated current 44.4 mA 40 mA 16.7 mA 12.5 mA
Coil resistance 101 Ω 125 Ω 720 Ω 1,920 Ω
Set Armature OFF
0.12 0.14 0.60 1.98
Armature ON
0.074 0.088 0.41 1.23
Reset Armature OFF
0.082 0.098 0.46 1.34
Armature ON
0.14 0.16 0.54 2.23
Must set voltage 75% max. of rated voltage
Must reset voltage 75% min. of rated voltage
Max. voltage 170% of rated voltage at 23°C 140% of rated
voltage at 23˚C
Power consumption Approx. 200 mW Approx. 300 mW
Coil ind-
uctance
(H) (ref.
value)
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
Omron 08 Cat 1-302 5/10/07 15:39 Page 232