Datasheet
223
Text
222
Text Surface-Mounting Signal Relay – G6K
■
Contact Ratings
Load Resistive load
Rated load 0.3 A at 125 VAC; 1 A at 30 VDC
Contact material Ag (Au-alloy)
Rated carry current 1 A
Max. switching voltage 125 VAC, 60 VDC
Max. switching current 1 A
■
Characteristics
Item Single-side stable models (double-pole) Single-winding latching
model
G6K-2F, G6K-2G, G6K-2P G6K-2F-Y, G6K-2G-Y, G6KU-2F-Y, G6KU-2G-Y,
G6K-2P-Y G6KU-2P-Y
Contact resistance 100 mΩ max.
(see note 1)
Operating (set) time 3 ms max. (approx. 1.4 ms) 3 ms max. (approx. 1.2 ms)
(see note 2)
Release (reset) time 3 ms max. (approx. 1.3 ms) 3 ms max. (approx. 1.2 ms)
(see note 2)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
(see note 3)
Coil & contacts 1,500 VAC, 50/60 Hz for 1 min
Contacts of 1,000 VAC, 50/60 Hz for 1 min
different polarity
Contacts of 750 VAC, 50/60 Hz for 1 min
same polarity
Coil & contacts 1,500 V (10 x 160 µs) 2,500 V (2 x 10 µs), 1,500 V (10 x 160 µs)
Contacts of 1,500 V (10 x 160 µs)
different polarity
Contacts of –
same polarity
Vibration resistance Destruction: 10 to 55 Hz, 2.5-mm single amplitude (5-mm double amplitude)
and 55 to 500 Hz, 300 m/s
2
(approx. 30G)
Malfunction: 10 to 55 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
and 55 to 500 Hz, 200 m/s
2
(approx. 20G)
Shock resistance Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: 750 m/s
2
(approx. 75G)
Endurance Mechanical: 50,000,000 operations min. (at 36,000 operations/hour)
Electrical: 100,000 operations min. (with a rated load at 1,800 operations/hour)
Failure rate (P level) 10 µA at 10 mVDC
(see note 4)
Ambient temperature Operating: -40°C to 70°C (with no icing or condensation)
Ambient humidity Operating: 5% to 85%
Weight Approx. 0.7 g
Note: The above values are initial values.
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC Megger Tester applied to the same parts as those used for checking
the dielectric strength.
4. This value was measured at a switching frequency of 120 operations/min.
Dielectric
strength
Impulse
withstand
voltage
Signal Relays
Surface-Mounting Signal Relay – G6K
Specifications
Contact mechanism: Bifurcated crossbar Ag (Au-alloy contact)
Enclosure ratings: Fully sealed
Application Examples
Telephones, communications equipment, measurement devices, office automation machines, and audio–visual products.
■
Coil Ratings
Single-side Stable Models – G6K-2F, G6K-2G, G6K-2P
Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC
Rated current 33.0 mA 23.2 mA 21.1 mA 9.1 mA
Coil resistance 91 Ω 194 Ω 237 Ω 1,315 Ω
Must operate voltage 80% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 150% of rated voltage at 23°C to 70°C
Power consumption Approx. 100 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23˚C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
Single-side Stable Models (Bellcore Version) – G6K-2F-Y, G6K-2G-Y, G6K-2P-Y
Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC
Rated current 33.0 mA 23.2 mA 21.1 mA 9.1 mA 4.6 mA
Coil resistance 91 Ω 194 Ω 237 Ω 1,315 Ω 5,220 Ω
Must operate voltage 80% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 150% of rated voltage at 23°C to 70°C
Power consumption Approx. 100 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23˚C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
Single-winding Latching Models (Bellcore Version) – G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y
Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC
Rated current 33.0 mA 23.2 mA 21.1 mA 9.1 mA 4.6 mA
Coil resistance 91 Ω 194 Ω 237 Ω 1,315 Ω 5,220 Ω
Must Set voltage 75% max. of rated voltage
Must reset voltage 75% max. of rated voltage
Max. voltage 150% of rated voltage at 23°C to 70°C
Power consumption Approx. 100 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23˚C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.