Datasheet

3
G6K Surface Mounting Relay
G
6
K
Ratings
Coil: Single-side Stable Models
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance
of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
Coil: Single-winding Latching Models (G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y)
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance
of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
Characteristics
Note: The above values are initial values.
Item
Rated voltage
Rated
current
(mA)
Coil
resistance
(Ω)
Must operate
voltage (V)
Must release
voltage (V)
Max. voltage
(V)
Power
consumption
(mW)
% of rated voltage
3 VDC 33.0 91
80% max. 10% min. 150%
Approx.
100
4.5 VDC 23.2 194
5 VDC 21.1 237
12 VDC 9.1 1,315
24 VDC 4.6 5,220
Item
Rated voltage
Rated
current
(mA)
Coil
resistance
(Ω)
Must operate
voltage (V)
Must release
voltage (V)
Max. voltage
(V)
Power
consumption
(mW)
% of rated voltage
3 VDC 33.0 91
75% max. 75% max. 150%
Approx.
100
4.5 VDC 23.2 194
5 VDC 21.1 237
12 VDC 9.1 1,315
24 VDC 4.6 5,220
Relay Function Single-side stable models Single-winding latching models
Item G6K-2F, G6K-2G, G6K-2PG6K-2F-Y, G6K-2G-Y, G6K-2P-YG6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y
Contact resistance *1 100 mΩ max.
Operating (set) time 3 ms max.
Release (reset) time 3 ms max.
Minimum set/reset signal width 10 ms
Insulation resistance *2 1,000 MΩ min. (at 500 VDC)
Dielectric
strength
Between coil and
contacts
1,500 VAC, 50/60 Hz for 1 min
Between contacts of
different polarity
1,000 VAC, 50/60 Hz for 1 min
Between contacts of
the same polarity
750 VAC, 50/60 Hz for 1 min
Impulse
withstand
voltage
Between coil and
contacts
1,500 V (10 × 160 μs) 2,500 V (2 × 10 μs), 1,500 V (10 × 160 μs)
Between contacts of
different polarity
1,500 V (10 × 160 μs)
Between contacts of
the same polarity
Vibration
resistance
Destruction 10-55-10 Hz, 2.5 mm single amplitude (5 mm double amplitude) and 55 to 500 Hz, 300 m/s
2
Malfunction 10-55-10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) and 55 to 500 Hz, 200 m/s
2
Shock
resistance
Destruction 1,000 m/s
2
Malfunction 750 m/s
2
Durability
Mechanical 50,000,000 operations min. (at 36,000 operations/hour)
Electrical 100,000 operations min. (with a rated load at 1,800 operations/hour)
Failure rate (P level) *3 10 μA at 10 mVDC
Ambient operating temperature -40 to 70°C (with no icing or condensation)
Ambient operating humidity 5% to 85%
Weight Approx. 0.7 g
Contacts
Item Load Resistive load
Contact type Bifurcated crossbar
Contact material Ag (Au-Alloy contact)
Rated load
0.3 A at 125 VAC,
1 A at 30 VDC
Rated carry current 2 A
Max. switching voltage 125 VAC, 60 VDC
Max. switching current 1 A
*1. The contact resistance was measured with 10 mA at 1
VDC with a voltage-drop method.
*2. The insulation resistance was measured with a 500 VDC
megohmmeter applied to the same parts as those used for
checking the dielectric strength.
*3. This value was measured at a switching frequency of 120
operations/min and the criterion of contact resistance is
50 Ω. This value may vary depending on the switching
frequency and operating environment. Always
double-check relay suitability under actual operating
conditions.