Datasheet
213
Text
212
Text Surface-Mounting Signal Relay – G6J-Y
■
Characteristics
Item Single-side Stable Relays Single-winding Latching Relays
G6J-2P-Y, G6J-2FS-Y, G6J-2FL-Y G6JU-2P-Y, G6JU-2FS-Y, G6JU-2FL-Y
Contact resistance (See note 1.) 100 mΩ max.
Operating (set) time (See note 2.) 3 ms max. (approx. 1.6 ms)
Release (reset) time (See note 2.) 3 ms max. (approx. 1.0 ms) 3 ms max. (approx. 0.9 ms)
Minimum set/reset signal width – 10 ms
Insulation resistance (See note 3.) 1,000 MΩ min. (at 500 VDC)
Coil & contacts 1,500 VAC, 50/60 Hz for 1 min
Contacts of dif- 1,000 VAC, 50/60 Hz for 1 min
ferent polarity
Contacts of 750 VAC, 50/60 Hz for 1 min
same polarity
Coil & contacts 2,500 VAC, 2 x 10 µs
Contacts of dif- 1,500 VAC, 10 x 160 µs
ferent polarity
Contacts of
same polarity
Vibration resistance Destruction: 10 to 55 Hz 2.5mm single amplitude (5mm double amplitude)
Malfunction: 10 to 55 Hz 1.65mm single amplitude (3.3mm double amplitude)
Shock resistance Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: 750 m/s
2
(approx. 75G)
Life expectancy Mechanical: 50,000,000 operations min. (at 36,000 operations/hour)
Electrical: 100,000 operations min. (with a rated load at 1,800 operations/hour)
Failure rate (P level) (See note 4.) 10 µA at 10 mVDC
Ambient temperature -40 to 85°C (with no icing or condensation)
Ambient humidity 5% to 85%
Weight Approx. 1 g
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC Megger Tester applied to the same parts as those for checking the
dielectric strength.
4. This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 5% of the
load impedance. This value may vary depending on the operating frequency, operating conditions, expected reliability level of
the relay, etc. Always double-check relay suitability under actual load conditions.
5. The above values are initial values.
Dielectric
strength
Impulse with
stand voltage
Signal Relays
Surface-Mounting Signal Relay – G6J-Y
Standard Specifications
Contact mechanism: Crossbar twin Ag (Au-alloy contact)
Enclosure rating: Plastic-sealed
■
Contact Ratings
Load Resistive load
Rated load 0.3 A at 125 VAC; 1 A at 30 VDC
Contact material Ag (Au-alloy)
Rated carry current 1 A
Max. switching voltage 125 VAC, 110 VDC
Max. switching current 1 A
■
Coil Rating
Single-side Stable Relays (G6J-2P-Y, G6J-2FS-Y, G6J-2FL-Y)
Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC
Rated current 48.0 mA 32.6 mA 28.9 mA 12.3 mA 9.2 mA
Coil resistance 62.5 Ω 137.9 Ω 173.1 Ω 976.8 Ω 2,600.5 Ω
Must operate voltage 75% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 150% of rated voltage
Power consumption Approx. 140 mW Approx. 230 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.
Single-winding Latching Relays (G6JU-2P-Y, G6JU-2FS-Y, G6JU-2FL-Y)
Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC
Rated current 33.7 mA 22.0 mA 20.4 mA 9.0 mA 5.2 mA
Coil resistance 89.0 Ω 204.3 Ω 245.5 Ω 1,329.2 Ω 4,619.2 mA
Must set voltage 75% max. of rated voltage
Must reset voltage 75% max. of rated voltage
Max. voltage 150% of rated voltage
Power consumption Approx. 100 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.
Omron 08 Cat 1-302 5/10/07 15:39 Page 212