G6E Low Signal Relay
G
6
E
Ratings
Coil: Single-side Stable
Coil: Single-winding latching
Coil: Double-winding latching
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2.Operating characteristics are measured at a coil temperature of 23°C.
3.The maximum voltage is the highest voltage that can be imposed on the relay coil.
4.Refer to the engineering data for relations between the ambient temperature and maximum coil voltage.
Contacts
Classification Rated voltage
Rated
current
(mA)
Coil
resistance
(Ω)
Must operate
voltage
(V)
Must release
voltage
(V)
Max.
voltage
(V)
Power
consumption
(mW)
% of rated voltage
Standard
5 VDC 40.0 125
70% max. 10% min.
190%
(at 23°C)
Approx. 200
6 VDC 33.3 180
9 VDC 22.2 405
12 VDC 16.7 720
24 VDC 8.3 2,880
48 VDC 8.3 5,760
170%
(at 23°C)
Approx. 400
Low-sensitivity
5 VDC 79.4 63
70% max. 10% min.
170%
(at 23°C)
Approx. 400
6 VDC 66.6 90
9 VDC 44.3 203
12 VDC 33.3 360
24 VDC 16.7 1,440
Contact type Rated voltage
Rated current
(mA)
Coil resistance
(Ω)
Must set voltage
(V)
Must reset voltage
(V)
Max. voltage
(V)
Power consumption
% of rated voltage Set coil (mW) Reset coil (mW)
Bifurcated
crossbar
5 VDC 40.0 125
70% max. 70% max.
190%
(at 23°C)
Approx. 200 Approx. 200
6 VDC 33.3 180
9 VDC 22.2 405
12 VDC 16.7 720
24 VDC 8.3 2,880
Classification Rated voltage
Rated current (mA) Coil resistance (Ω)
Must set
voltage
(V)
Must reset
voltage
(V)
Max.
voltage
(V)
Power consumption
Set coil Reset coil Set coil Reset coil % of rated voltage
Set coil
(mW)
Reset coil
(mW)
Standard
5 VDC 40.0 40.0 125 125
70% max. 70% max.
190%
(at 23°C)
Approx. 200 Approx. 200
6 VDC 33.3 33.3 180 180
9 VDC 22.2 22.2 405 405
12 VDC 16.7 16.7 720 720
24 VDC 8.3 8.3 2,880 2,880
Low-sensitivity
5 VDC 79.4 79.4 63 63
70% max. 70% max.
170%
(at 23°C)
Approx. 400 Approx. 400
6 VDC 66.6 66.6 90 90
9 VDC 44.3 44.3 203 203
12 VDC 33.3 33.3 360 360
24 VDC 16.7 16.7 1,440 1,440
Load
Item
Resistive load
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Contact type Bifurcated crossbar
Contact material Ag (Au-Alloy)
Rated load
0.4 A at 125 VAC;
2 A at 30 VDC
0.2 A at 125 VAC;
1 A at 30 VDC
Rated carry current 3 A
Max. switching voltage 250 VAC, 220 VDC
Max. switching current 3 A