Datasheet

6
G6E Low Signal Relay
G
6
E
Approved Standards
The approval rating values for overseas standards are different from the performance values determined individually. Confirm the
values before use.
UL recognized: (File No. E41515)
CSA certified: (File No. LR31928)
Precautions
Please refer to “PCB Relays Common Precautions” for correct use.
Model
Contact
form
Coil ratings Contact ratings
Number of test
operations
G6E( )-134P( )US
SPDT
(1c)
5 to 48
VDC
0.2 A, 250 VAC
6,000
0.6 A, 125 VAC
2 A, 30 VDC
0.6 A, 125 VDC
Long-term Continuously ON
Contacts
Using the Relay in a circuit where the
Relay will be ON continuously for long
periods (without switching) can lead to
unstable contacts because the heat
generated by the coil itself will affect
the insulation, causing a film to
develop on the contact surfaces. We
recommend using a latching relay
(magnetic-holding relay) in this kind of
circuit. If a single-side stable model
must be used in this kind of circuit, we
recommend using a fail-safe circuit
design that provides protection against
contact failure or coil burnout.
Mounting
Do not reverse the polarity of the coil
(+, ).
Provide sufficient space between
Relays when mounting two or more on
the same PCB, as shown in the
following diagram.
Wiring
Refer to the following diagram when
wiring to switch a DC load. The
difference in polarity applied to the
contacts will affect the endurance of
the Relay due to the amount of contact
movement. To extend the endurance
characteristics beyond the
performance ratings, wire the common
(pin 7) terminal to the positive (+) side.
Ultrasonic Cleaning
Do not use ultrasonic cleaning on
standard relay models. Doing so may
result in resonance, coil burnout, and
contact adhesion within the Relay.
Use a model designed for ultrasonic
cleaning if ultrasonic cleaning is
required.
Relay Handling
When washing the product after
soldering the Relay to a PCB, use a
water-based solvent or alcohol-based
solvent, and keep the solvent
temperature to less than 40°C. Do not
put the Relay in a cold cleaning bath
immediately after soldering.
Correct Use
Close
mounting
Distance between terminals:
2.54 × 2 (pitch) max.
Load Load
Wiring Diagram
7
1012
+
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K024-E1-11
0617(0207)(O)
Note: Do not use this document to operate the Unit.