Datasheet

114
G6AG6A
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
2. Orientation marks are indicated as follows:
Precautions
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON continu-
ously for long periods (without switching) can lead to unstable
contacts because the heat generated by the coil itself will affect
the insulation, causing a film to develop on the contact surfaces.
We recommend using a latching relay (magnetic-holding relay) in
this kind of circuit. If a single-side stable model must be used in
this kind of circuit, we recommend using a fail-safe circuit design
that provides protection against contact failure or coil burnout.
Relay Handling
When washing the product after soldering the Relay to a PCB,
use a water-based solvent or alcohol-based solvent, and keep the
solvent temperature to less than 40°C. Do not put the Relay in a
cold cleaning bath immediately after soldering.
Double-swicthing load in two poles
Double-switching in two poles as shown in the figure below, one
pole and two pole interval may become MBB(Make Before
Break) mechanically according to the timing of the point of con-
tact switching (By the short-circuit mode), and the malfunction
might be caused.
In such a circuit, direct electric switching should be avoided, and
concern for contact to be carried after the contact of Relay abso-
lutely switches in condition of no load.
G6A-274P-ST(40)-US
Terminal Arrangement/
Internal Connections
(Bottom View)
Mounting Holes
(Bottom View)
Tolerance: ±0.1
G6AK-274P-ST(40)-US
1
16
4
13
6
11
8
9
+
-
7.62
5.08 5.08
(1.2)
7.62
(1.2)
(1.2)
(1.2)
Eight, 1.0-dia. holes
20.2 max.
(20)*
0.6
10.1 max.
(9.9)*
8.4 max.
(8.2)*
0.64
7.62
0.3
3.16
20.2 max.
(20)*
0.6
10.1 max.
(9.9)*
8.4 max.
(8.2)*
0.64
7.62
0.3
3.16
Terminal Arrangement/
Internal Connections
(Bottom View)
Mounting Holes
(Bottom View)
Tolerance: ±0.1
1
16
4
13
6
11
8
9
+
-
+
-
2
15
SR
2.54
5.08 5.08
(1.2)
7.62
(1.2)
(1.2)
(1.2)
5.08
Ten, 1-dia. holes
*Average value
*Average value
G6AU-274P-ST-US
20.2 max.
(20)*
0.6
10.1 max.
(9.9)*
8.4 max.
(8.2)*
0.64
7.62
0.3
3.16
Terminal Arrangement/
Internal Connections
(Bottom View)
Mounting Holes
(Bottom View)
Tolerance: ±0.1
1
16
4
13
6
11
8
9
+ -
- +
S R
7.62 5.08 5.08
(1.2)
7.62
(1.2)
(1.2)
(1.2)
Eight, 1.0-dia. holes
*Average value
Load
Contacts
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K020-E1-09