Datasheet

112
G6AG6A
Characteristics
Note: The data shown above are initial values.
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking
the dielectric strength (except between the set and reset coil).
Approved Standards
UL (File No. E41515)/CSA (File No. LR31928)
Contact resistance (See note 1.) 50 mΩ max.
Operate (set) time (See note 2.) Single-side stable types:
5 ms max. (approx. 3 ms)
Latching types:
5 ms max. (approx. 2.5 ms)
Release (reset) time (See note 2.) Single-side stable types:
3 ms max. (approx. 1.2 ms)
Latching types:
5 ms max. (approx. 2.5 ms)
Min. set/reset signal width 10 ms min.
Max. operating frequency Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance (See note 3.) 1,000 MΩ min. (at 500 VDC); except for set-reset
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
250 VAC, 50/60 Hz for 1 min between set and reset coils
Impulse withstand voltage 1,500 V (10 x 160 µs) (conforms to FCC Part 68)
Vibration resistance Destruction: 10 to 55 to 10 Hz, 2.5-mm single amplitude (5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
Shock resistance
Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: 500 m/s
2
(approx. 50G)
Endurance Mechanical: 100,000,000 operations min. (at 36,000 operations/hr)
Electrical: 500,000 operations min. (at 1,800 operations/hr)
Ambient temperature Operating: 40°C to 70°C (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 3.5 g
Model Contact form Coil ratings Contact ratings
G6A-274P-ST(40)-US
G6AK-274P-ST(40)-US
G6AU-274P-ST-US
DPDT 3 to 48 VDC 0.6 A, 125 VAC
2 A, 30 VDC
0.6 A, 110 VDC