Datasheet
253
Text
252
Text PCB Signal Relay – G6A
■
Contact Ratings
Item G6A-234P-ST(40)-US/434P-ST(40)-US G6A-274P-ST(40)-US/474P-ST(40)-US
Load Resistive load Inductive load Resistive load Inductive load
(cosϕ = 1) (cosϕ = 0.4; L/R = 7 ms) (cosϕ = 1) (cosϕ = 0.4; L/R = 7 ms)
Rated Load 0.3 A at 125 VAC; 0.2 A at 125 VAC; 0.5 A at 125 VAC; 0.3 A at 125 VAC;
1 A at 30 VDC 0.5 A at 30 VDC 2 A at 30 VDC 1 A at 30 VDC
Contact Material AgPd (Au-clad) Ag (Au-clad)
Rated Carry Current 3 A
Max. switching voltage 250 VAC, 220 VDC
Max. switching current 2 A 1 A 2 A 1 A
Max. switching power 125 VA, 60 W 62.5 VA, 30 W 125 VA, 60 W 62.5 VA, 30 W
Failure rate (reference value) 0.01 mA at 10 mVDC
Item G6AK-234P-ST(40)-US/G6AK-434P-ST(40)-US GG6AK-274P-ST(40)-US/G6AK-474P-ST(40)-U
G6AU-234P–ST-US/G6AU-434P-ST-US G6AU-274P-ST-US/G6AU-474P-ST-US
Load Resistive load Inductive load Resistive load Inductive load
(cosϕ = 1) (cosϕ = 0.4; L/R = 7 ms) (cosϕ = 1) (cosϕ = 0.4; L/R = 7 ms)
Rated Load 0.3 A at 125 VAC; 0.2 A at 125 VAC; 0.5 A at 125 VAC; 0.25 A at 125 VAC;
1 A at 30 VDC 0.5 A at 30 VDC 2 A at 30 VDC 1 A at 30 VDC
Contact Material AgPd (Au-clad) Ag (Au-clad)
Rated Carry Current 3 A 3 A
Max. switching voltage 250 VAC, 220 VDC 250 VAC, 220 VDC
Max. switching current 2 A 1 A 2 A 1 A
Max. switching power 125 VA, 60 W 62.5 VA, 30 W 125 VA, 60 W 62.5 VA, 30 W
Failure rate (reference value) 0.01 mA at 10 mVDC 0.01 mA at 10 mVDC
Note: P level: λ
60
= 0.1 x 10
-6
/operation.
This value was measured at a switching frequency of 60 operations/min and the criterion of contact resistance is 50Ω. This
value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under
actual operating conditions.
Signal Relays
PCB Signal Relay – G6A
Rated voltage 3 VDC 4.5 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 48 VDC
Rated current 120 mA 79.9 mA 72.5 mA 60 mA 40 mA 30 mA 15 mA 7.5 mA
Coil resistance 25 Ω 56.3 Ω 69 Ω 100 Ω 225 Ω 400 Ω 1,600 Ω 6,400 Ω
Coil inductance Set Armature OFF
0.015 0.04 0.05 0.07 0.16 0.28 1.1 4
(H) (ref. value) Armature ON
0.01 0.025 0.035 0.05 0.12 0.2 0.75 2.9
Reset Armature OFF
0.01 0.025 0.035 0.05 0.12 0.2 0.75 2.9
Armature ON
0.015 0.04 0.05 0.07 0.16 0.28 1.1 4
Must operate voltage 70% max. of rated voltage
Must release voltage 70% max. of rated voltage
Max. voltage 150% of rated voltage at 23°C
Power consumption Approx. 360 mW
Double-winding Latching, Low-sensitivity DPDT Relays
Rated voltage 3 VDC 4.5 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 48 VDC
Rated current 120 mA 79.9 mA 72.5 mA 60 mA 40 mA 30 mA 15 mA 7.5 mA
Coil resistance 25 Ω 56.3 Ω 69 Ω 100 Ω 225 Ω 400 Ω 1,600 Ω 6,400 Ω
Coil inductance Set Armature OFF
0.02 0.045 0.065 0.09 0.18 0.3 1.2 4.4
(H) (ref. value) Armature ON
0.015 0.035 0.05 0.075 0.14 0.23 0.82 3.2
Reset Armature OFF
0.015 0.035 0.05 0.075 0.14 0.23 0.82 3.2
Armature ON
0.02 0.045 0.065 0.09 0.18 0.3 1.2 4.4
Must operate voltage 70% max. of rated voltage
Must release voltage 70% max. of rated voltage
Max. voltage 150% of rated voltage at 23°C
Power consumption Approx. 360 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
Double-winding Latching, Low-sensitivity 4PDT Relays
Omron 08 Cat 1-302 5/10/07 15:39 Page 252